Installation Sheet
42 Rinnai Tankless Water Heater Installaon and Operaon Manual
OUT
IN
OUT
Cascade
Cable
With use of cascade cable(s) up to 24 water heaters can be electronically connected. This connecon will rotate water
heater operaon order to ensure equal usage among the enre system and enables all water heaters connected to
modulate operaon and funcon as one hot water source.
Cascade Cable Required:
• Cable length: 26 ft (8 m)
OR
• Cable Length:10 ft (3 m)
• One cable required for
each water heater.
• Includes 1 cable and 2 cascade jumpers.
Primary
Secondary 1
NOTE: For proper operaon, do not combine dierent
models with cascade communicaon.
1. Connect one end of the Cascade Cable to the “Cascade
OUT” accessory port on the PCB.
2. Connect the other end of the cascade cable to the
“Cascade IN” accessory port on the PCB of the next
water heater.
3. Repeat steps 1 and 2 for each subsequent water
heater in the system.
4. Connect the “Cascade Jumper” (Included with the
cascade cable) to the open accessory ports.
5. Proceed to “Programing Cascade Communicaon” on
the following page.
Primary
PCB
Secondary 1
PCB
Secondary 2
-23
Secondary 2
PCB
Accessory
Port
Locaon
Cascade IN
Cascade OUT
IN
Cascade
Jumper
Cascade
Jumper
Cascade Cable Assembly
Connecng Mulple Water Heaters (Cascade Communicaon)