Installation Sheet
44 Rinnai Tankless Water Heater Installaon and Operaon Manual
• The piping (including soldering materials) and components connected to this appliance must be approved for use in
potable water systems.
• Purge the water line to remove all debris and air. Debris will damage the water heater.
• The appliance must not be connected to a system that was previously used with a non-potable water heang
appliance.
• Ensure that the water lter on the water heater is clean and installed.
• DO NOT introduce toxic chemicals such as those used for boiler water treatment to the potable water used for
space heang.
To connect the water supply, follow the instrucons below.
IMPORTANT: Water connecons to the water heater should follow all state and local plumbing codes.
If this is a standard installaon, refer to the “Piping Diagram for Basic Installaon” below.
1. Plumb the cold water supply line to the water heater on the 3/4 in. MNPT connecon at the boom of the water
heater marked “COLD.”
2. Plumb the hot water supply line to the 3/4 in. MNPT connecon marked “HOT.”
3. If a pipe cover will be installed, make sure water lines to the water heater t within the connements of the pipe
cover.
The condensate drain pipe (along its enre
length) must be at least the same diameter
as the drain line (1/2 in. NPT).
Refer to secon “3.9 Condensate” for more
informaon.
PIPING DIAGRAM FOR BASIC INSTALLATION
3.6 Connect the Water Supply
Floor Drain
Gas Supply Line
Cold Water Supply Line
Hot Water Supply Line
Condensate
Drain Line
Guidelines
Instrucons