Installation Sheet

44 Rinnai Tankless Water Heater Installaon and Operaon Manual
The piping (including soldering materials) and components connected to this appliance must be approved for use in
potable water systems.
Purge the water line to remove all debris and air. Debris will damage the water heater.
The appliance must not be connected to a system that was previously used with a non-potable water heang
appliance.
Ensure that the water lter on the water heater is clean and installed.
DO NOT introduce toxic chemicals such as those used for boiler water treatment to the potable water used for
space heang.
To connect the water supply, follow the instrucons below.
IMPORTANT: Water connecons to the water heater should follow all state and local plumbing codes.
If this is a standard installaon, refer to the Piping Diagram for Basic Installaonbelow.
1. Plumb the cold water supply line to the water heater on the 3/4 in. MNPT connecon at the boom of the water
heater marked COLD.
2. Plumb the hot water supply line to the 3/4 in. MNPT connecon marked HOT.
3. If a pipe cover will be installed, make sure water lines to the water heater t within the connements of the pipe
cover.
The condensate drain pipe (along its enre
length) must be at least the same diameter
as the drain line (1/2 in. NPT).
Refer to secon “3.9 Condensatefor more
informaon.
PIPING DIAGRAM FOR BASIC INSTALLATION
3.6 Connect the Water Supply
Floor Drain
Gas Supply Line
Cold Water Supply Line
Hot Water Supply Line
Condensate
Drain Line
Guidelines
Instrucons