Installation Sheet

Rinnai Tankless Water Heater Installaon and Operaon Manual 53
WARNING
Do not use an extension cord or adapter plug with this appliance.
The water heater must be electrically grounded in accordance with local codes and ordinances or, in the absence
of local codes, in accordance with the Naonal Electrical Code, ANSI/NFPA No. 70.
Indoor water heaters are equipped with a three-prong (grounding) plug for your protecon against shock hazard
and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding terminal from this plug.
Conrm that the electricity is supplied from 120 VAC, 60 Hz power source and is in a properly grounded circuit.
Conrm that an extension cord or an adapter plug has NOT been used with the water heater.
Guidelines
3.11 Connect the Power Supply
Post-Power Supply Connecon Checklist
When connecng the power supply, follow these guidelines:
Do not rely on the gas or water piping to ground the water heater. Ground locaons are provided inside the water
heater.
The water heater requires 120 VAC, 60 Hz power from a properly grounded circuit.
If using the 5  (1.5 m) power cord (supplied with internal/indoor water heaters), plug it into a standard 3 prong
120 VAC, 60 Hz properly grounded wall outlet.
On external (outdoor) models, a disconnect switch must be provided and installed for the incoming 120 VAC
power. The switch should be a type that is suitable for outdoor use. Check the Naonal Electrical Code, ANSI/NFPA
70 and your local codes for a proper switch type to use in your area. Power connecons must be protected from
the weather and exible cords must use an appropriate strain relief.
The wiring diagram is located on the inside of the water heater front cover.
Disconnect switch (required on external (outdoor) models)
Ground connecon screw
120V Wiring
White wire (Neutral)
Black wire (Hot leg)