Installation Sheet
60 Rinnai Tankless Water Heater Installaon and Operaon Manual
4.4 Performance Data
To Obtain Performance Data:
1. Press and hold the (Down) buon.
2. While holding the (Down) buon for 2 seconds,
press and hold the “On/O” buon (hold both buons
simultaneously).
3. Use the (Up) and (Down) buons to scroll to the
desired informaon described in the Performance
Data Table.
4. To exit performance data, repeat step 2 above.
5. When complete, the set temperature appears in the
display.
1
2
# DATA UNIT
01
Water Flow Rate x0.1 gal/min
02
Outgoing Temperature °F
03
Combuson Hours x100 Hours
04
Combuson Cycles *
05
Fan Frequency Hz
06
Addional Controllers Connected *
07
Water Flow Control Posion
0=mid, 1=Open,
2=Closed
08
Inlet Temperature °F
09
Fan Current x10 mA
10
Total Bath Fill Amount gallons
11
HEX Outlet Temperature °F
12
By-Pass Flow Control Posion Degrees of opening
15
Freeze Protecon Temperature
(Indoor Unit Only)
°F
17
Freeze Protecon Temperature
(Outdoor Unit Only)
°F
19
Pump Hours x100 Hours
20
Pump Cycles *
21
Exhaust Temperature °F
Performance Data Table
* Refer to the Technical Data Sheet located on the inside
front cover of the water heater for addional informaon.
# DATA UNIT
01
Water Flow Rate x0.1 gal/min
02
Outgoing Temperature °F
03
Combuson Hours x100 Hours
04
Combuson Cycles *
05
Fan Frequency Hz
06
Addional Controllers Connected *
07
Water Flow Control Posion
0=mid, 1=Open,
2=Closed
08
Inlet Temperature °F
09
Fan Current x10 mA
10
Total Bath Fill Amount Gallons
11
HEX Outlet Temperature °F
12
By-Pass Flow Control Posion Degrees of opening
15
Freeze Protecon Temperature
(Indoor Units Only)
°F
17
Freeze Protecon Temperature
(Outdoor Units Only)
°F
19
Pump Hours x100 Hours
20
Pump Cycles *
21
Exhaust Temperature °F
Performance Data Table
The water heater can deliver water at only one temperature seng at a me. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/O” buon on
the controller for 5 seconds while the water heater is OFF.
These models have a default maximum temperature of 140° F (60° C) and an opon to increase the maximum temperature
to 185 °F (85 °C) with parameter adjustment. Refer to secon “3.12 Parameter Sengs” for further details.
Temperature Sengs
Parameter
Seng A
°F 98 100 102 104 106 108 110 115 120 125 130 135 140* 150* 160* 185*
°C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85
°F 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185
Parameter
Seng
°C 43 46 49 52 54 57 60 63 66 68 71 74 77 79 82 85
Available Temperatures with an Internal Controller