4.5 Diagnosc Codes
Some of the checks below should be performed by a licensed professional. Consumers
should never aempt any acon that they are not qualied to perform.
WARNING
To display diagnosc codes:
1. Turn o the water heater by pressing the On/Obuon.
2. Press and hold the On/Ofor 2 seconds and then the (Up)
buon simultaneously.
3. The last 9 maintenance codes display and ash one aer the other.
4. To exit diagnosc codes and return the water heater to normal
operaon, press and hold the On/Obuon for 2 seconds and then
the (Up) buon simultaneously.
5. Turn on the water heater by pressing the On/Obuon.
1
2
03
Power interrupon during bath ll
(Water will not ow when power returns)
Turn o all hot water taps. Press ON/OFF twice.
05
By-Pass Flow Control
Measure resistance values of the by-pass ow control.*
Replace By-Pass ow control device.
10
Air Supply or Exhaust Blockage/Condensate Trap
is Full
Ensure condensate line is not blocked.
Ensure internal air lter is clean with no obstrucons.
(Indoor Water Heaters Only)
Ensure High Altude seng. (See Parameter Sengs)
Ensure Combuson air and Exhaust vents are not blocked
and approved venng materials are being used. (Indoor
Water Heaters Only)
Ensure vent length is within limits. (Indoor Water Heaters
Only)
Check fan for debris and ensure wheel turns freely.
Verify check valve is not stuck between fan casing and
burner body.
11
No Ignion (Heater Not Turning On)
Check that the gas is turned on at the water heater,
meter, or cylinder.
If the system is propane, make sure that gas is in the tank.
Ensure gas type and inlet gas pressure are correct.
Bleed all air from gas lines.
Check the ground wire for the PC Board.
Ensure ame rod wire is connected.
Ensure igniter is operaonal.*
Check gas solenoid valves for open or short circuits.*
Verify gas orice is correct.
12
No Flame
Check that the gas is turned on at the water heater, gas
meter, or cylinder.
If the system is propane, make sure that gas is in the tank.
Ensure ame rod wire is connected.
Ensure gas type and inlet gas pressure is correct.
Bleed all air from gas lines.
14
Heat Exchanger Overheat
Measure resistance of Overheat Switch.*
Check heat exchanger surface for hot spots which indicate
blockage due to scale build-up.
Refer to instrucons in manual for ushing heat exchanger.
Hard water must be treated to prevent scale build up or
damage to the heat exchanger.
Ensure it is not forced Hi seng.
15
Venturi Control
Ensure the Venturi motor is operang correctly.*
Replace gas valve assembly.
Clear diagnosc code by reseng the main power supply
to the water heater.
16
High Outgoing Temperature
(safety shutdown because water heater is too
hot)
Conrm fan motor is funconing correctly.
Replace the gas valve assembly.
17
Venturi Blockage
Ensure Venturi isn't blocked.
Please call Rinnai technical department.
19
Electrical Grounding
Check all components for electrical short.
* See Electrical Diagnoscson Technical Data Sheet located on inside front cover of water heater.