FOR GAS MODELS SOLD IN MASSACHUSETTS
NOTICE BEFORE INSTALLATION:
This direct-vent appliance must be installed by a properly trained licensed professional. If you are not properly
trained, you must not install this unit.
IMPORTANT: In the State of Massachuses (248 CMR 4.00 & 5.00):
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in
whole or in part for residenal purposes, including those owned or operated by the Commonwealth and where the
side wall exhaust vent terminaon is less than 7 above nished grade in the area of the venng, including but not
limited to decks and porches, the following requirements shall be sased:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the me of installaon of the side wall horizontal vented
gas fueled equipment, the installing plumber or gaser shall observe that a hard wired carbon monoxide
detector with an alarm and baery back-up is installed on the oor level where the gas equipment is to be
installed. In addion, the installing plumber or gaser shall observe that a baery operated or hard wired
carbon monoxide detector with an alarm is installed on each addional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property
owner to secure the services of qualied licensed professionals for the installaon of hard wired carbon
monoxide detectors
A. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an
ac, the hard wired carbon monoxide detector with alarm and baery back-up may be installed on the next
adjacent oor level.
B. In the event that the requirements of this subdivision can not be met at the me of compleon of installaon,
the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however,
that during said thirty (30) day period, a baery operated carbon monoxide detector with an alarm shall be
installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the
above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS cered.
3. SIGNAGE. A metal or plasc idencaon plate shall be permanently mounted to the exterior of the building at a
minimum height of 8 above grade directly in line with the exhaust vent terminal for the horizontally vented gas
fueled heang appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size,
"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not
approve the installaon unless, upon inspecon, the inspector observes carbon monoxide detectors and signage
installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
6.5 Massachuses State Gas Regulaons