Installation Sheet
8 Rinnai Tankless Water Heater Installaon and Operaon Manual
2.5 Specicaons
Internal (Indoor) Units External (Outdoor) Units
CU199i CU160i CU199e CU160e
Minimum Gas Consumpon Btu/h
15,000
Maximum Gas Consumpon Btu/h 199,000 160,000 199,000 160,000
Flow Rate
1
(Min - Max)
0.26 - 9.8 GPM
(1.0 - 37 L/min)
0.26 - 8.0 GPM
(1.0 - 30 L/min)
0.26 - 9.8 GPM
(1.0 - 37 L/min)
0.26 - 8.0 GPM
(1.0 - 30 L/min)
Max Flow Rate with Parameter Adjustment
11 GPM
(42 L/min)
9 GPM
(34 L/min)
11 GPM
(42 L/min)
9 GPM
(34 L/min)
Weight 64 lb (29 kg) 62 lb (28 kg) 64 lb (29 kg) 62 lb (28 kg)
Sound level 49 dB 48 dB 53 dB 52 dB
Electrical
Data
Normal 84 W 52 W 81 W 49 W
Standby 1.3 W
Freeze Protecon 148 W 152 W
Max Current
4 Amps
Fuse 10 Amps
Temperature Seng
• Minimum: 98° F (37° C)
• Maximum: Default: 140° F (60° C) With Parameter Adjustment: 185° F (85° C)
By-Pass Flow Control Electronic
Gas Supply
Pressure
2
Natural 3.5 in. w.c. - 10.5 in. w.c.
Propane 8.0 in. w.c. - 13.5 in. w.c.
Type of Appliance
Super-High-Eciency (Condensing), Tankless, Temperature Controlled Connuous
Flow Gas Hot Water System
Ignion System Direct Electronic Ignion
Electric Connecons
• Appliance: AC 120 Volts, 60Hz.
• Temperature Controller: DC 12 Volts (Digital)
Water Supply Pressure
• Minimum: 50 PSI (Recommended 60-80 PSI for maximum performance)
• Maximum: 150 PSI
Remote Control Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualied Yes
Complies with South Coast Air Quality Management
District 14 ng/J or 20 ppm NOx emission levels
Yes
1
Minimum ow may vary slightly depending on the temperature seng and the inlet water temperature. Minimum acvaon ow is 0.4 GPM (1.5 L/min).
2
The maximum gas supply pressure must not exceed the value specied by the manufacturer.
Rinnai products are connually being updated and improved; therefore, specicaons are subject to change without prior noce.