Infinity 24e Continuous Flow Water Heater User's Manual

10 
TECHNICAL DETAILS 
    * Factory Setting 
  **Minimum operation flow based on temperature setpoint and inlet conditions. 
Infinity Model 
Infinity 24e 
Units 
Installation External   
Nat Gas Press Low  0.8  mbar 
Nat Gas Press High  9.0  mbar 
LPG Press Low  1.7  mbar 
LPG Press High  22.6  mbar 
Height 600 mm 
Width 350 mm 
Depth 170 mm 
Weight 18 kg 
Flue System  Forced Exhaust 
Temp. Range Controllers  37 - 75  deg C 
Temp. Range without 
Controllers 
37,40,43,50, 
55*,65,75 
deg C 
Ignition 
Direct Electronic  
Ignition 
Gas Consumption Low     
Nat Gas  5.8  kW 
LPG 5.8 kW 
Gas consumption High     
Nat Gas  52  kW 
LPG 52 kW 
Max Flow raised 33C  18  L/min 
Min Operation Flow  2.7**  L/min 
Water Pressure Nom.  1.4 - 10  bar 
Power Supply  230 V / 50 Hz 
Elec. Consumption Standby 
(with 1 remote connected) 
6 Watts 
Elec. Consumption Run  55  Watts 
Elec. Consumption  
Anti-frost Heaters On 
100 Watts 