Installation manual
103 International Drive
Peachtree City, Georgia 30269
RINNAI WATER HEATERS
Domestic Hot Water with Circulation
1 Rinnai Water Heater
This is not an engineered drawing, it is intended only as a guide and
no
t as a replacement for professionally engineered project drawings.
This drawing is not intended to describe a complete system, it is up
to the contractor/engineer to determine the necessary components
for and configuration of the particular system being installed. The
drawing does not imply compliance with local building code
requirements. It is the engineer/contractor responsiblity to ensure
the installation is in accordance with all local building codes. Confer
with
local building officials before installation.
Pressure Relief Valve
3/4" Ball Valve
3/4" Union
Check Valve
S
Pressure Regulator
Circulating Pump
Solenoid Valve
Boiler Drain Valve
KEY
Minimum 3/4" Hot Water
Supply Line
B
u
i
l
d
i
n
g
F
i
x
t
u
r
e
O
u
t
l
e
t
s
(Optional)
2-6 Gallon
Storage Tank
(To eliminate cold water
sandwich effect caused by
frequent On/Off operation)
Pump Should be Controlled by an
Aquastat, Timer or Combination
Aquastat and Timer
Pump to be sized for 3.0 gpm flow @ 12 feet head. Flow Balancing
Valve to be adjusted to 3 GPM flow through water heater with no hot
water taps open. Pump to be of Bronze or Stainless Construction.
Cold Water Supply and Circulation Return Lines Must Be 3/4"
Tubing Throughout Circulation Loop.
Note:
Water heater outlet temperature
cannot be adjusted when
circulation pump is running.
QTY
1
1
1
E
x
p
a
n
s
i
o
n
T
a
n
k
Rinnai
Water Heater
Note:
PLEASE NOTE FOR RESIDENTIAL
APPLICATIONS, THIS PIPING
ARRANGEMENT REDUCES
WARRANTY TO THE FOLLOWING:
3 Years On Heat Exchanger
3 Years On Parts
Rinnai
Equipment List
(Residential and
Commercial)
Rinnai
Water Heaters
(Indoor)
MC-91 Controller
(Included)
MC-100V and BC-100V
Controllers Optional
RIK-KIT (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain Valves and
1 Pressure Relief Valve.)
3
/
4
"
G
a
s
C
o
n
n
e
c
t
i
o
n
Commercial Application Warranty:
5 Years On Heat Exchanger
5 Years On Parts
G
a
s
S
u
p
p
l
y
V
e
n
t
i
n
g
E
q
u
i
p
m
e
n
t
L
i
s
t
(Residential and
I
n
d
o
o
r
U
n
i
t
P
l
e
a
s
e
R
e
v
i
e
w
V
e
n
t
i
n
g
I
n
s
t
r
u
c
t
i
o
n
s
/
G
u
i
d
e
l
i
n
e
s
f
o
r
P
r
o
p
e
r
C
o
m
p
o
n
e
n
t
s
a
n
d
I
n
s
t
a
l
l
a
t
i
o
n
.
Commercial)
33
Rinnai America
FF Models
INSTA L L E R ’ S I NSTA L L AT I O N IN S T R U C T I O N S
OPTIONAL PIPING FOR CIRCULATION SYSTEMS