Installation Guide
12 Hydronic Air Handler Installaon and Operaon Manual
2
Factory default setting for both heating and cooling.
Air Handler
Models
Speed
Air Flow (CFM) vs External Static Pressure (WC)
0.1 0.2 0.3 0.4 0.5
AH083P
AH083CP
Low 749 705 658 614 558
Med
2
865 815 760 708 646
High 904 836 801 740 681
AH084P
AH084CP
Low 749 705 658 614 558
Med
2
865 815 760 708 646
High 904 836 801 740 681
AH125P
AH125CP
Low 1198 1144 1086 1018 962
Med
2
1257 1198 1130 1072 1010
High 1273 1215 1158 1094 1018
AH166P
AH166CP
Low 1576 1514 1433 1338 1264
Med 1643 1576 1490 1407 1320
High
2
1707 1606 1545 1441 1364
AH206P
AH206CP
Low 1759 1691 1652 1580 1512
Med 1838 1788 1729 1644 1555
High
2
1928 1867 1810 1729 1637
3-Speed PSC Motor Speed Table
• Results are obtained while air handler is operating with a dry DX coil and air filter installed.
• Values are nominal and blower performance can vary higher or lower from these values based on the
evaporator coil that is used. Hot water heat air flow performance data includes associated air pressure
drop across a four-row hot water coil for models AH084P/CP, AH125P/CP, and AH166P/CP, and air
pressure drop across a three-row hot water coil for models AH083P/CP and AH206P/CP.
Domestic hot water recirculation circulates hot water through the plumbing system so that instant hot water is
available. Domestic hot water recirculation operates between calls for heat to ensure a balance of comfort for
HVAC heating and domestic hot water. If pairing a Rinnai Hydronic Air Handler with a tankless water heater for
domestic hot water recirculation capabilities, Rinnai recommends the following:
• Use an external recirculation pump controlled by a timer, aquastat, and/or an on-demand type control.
Do not use a Rinnai Tankless Water Heater equipped with recirculation capability
1
with the Rinnai
Hydronic Air Handler.
• Size the air handler based off of the maximum allowable temperature for the domestic hot water system.
Refer to section “5.7.3 Domestic Hot Water Recirculation Piping Diagrams” for domestic hot water recirculation
piping diagrams.
For more information on domestic hot water recirculation, refer to the tankless water heater installation and
operation manual.
1
Rinnai Tankless Water Heaters equipped with recirculation capability include the SE+ Series featuring ThermaCirc360™
models (Super High-Efficiency Plus RUR Models).
This section is referring to domestic hot water recirculation in the plumbing system and not the circulation
of hot water between the air handler and tankless water heater/boiler.
IMPORTANT