Spec Sheet
2
AH083CP AH084CP AH125CP AH166CP AH206CP
Installation Indoor (approved for manufactured housing and mobile homes)
Suitable for Potable Water Systems Yes
Configurations
• Vertical: Upflow with bottom or side (left or right side) return
• Horizontal: Upflow with bottom return
Circulation Pump Included Yes (Factory Installed)
Product Weight - lb. (kg) (approximate) 66 (30) 66 (30) 66 (30) 71 (32) 83 (38)
Cabinet Construction
Embossed cabinet in heavy gauge galvanized steel to prevent
corrosion. Cabinet lined with 5/8 in. foil faced insulation.
Nominal CFM (Cubic Feet/Minute) 800 800 1,200 1,600 2,000
Nominal Output Btu/hr at 140°F
1
30,000 40,000 50,000 60,000 60,000
Rated Voltage 120 V, 60 Hz, 1 Ph
Transformer Size and Type 40 VA, Class 2
Blower Wheel (Diameter x Width) 9x6 in. 9x6 in. 10x8 in. 10x8 in. 10x10 in.
Blower Motor Type 3-Speed PSC
Blower Motor Hot Water Coil Rows 3 4 3
Blower Motor Coil Material Copper Coil, UV Resistant Pan
Blower Motor Horsepower (HP) 1/3 1/3 1/2 3/4 3/4
Blower Full Load Amps (FLA) 5.3 5.3 7.1 7.5 10.5
Water Connection 3/4 in. Sweat
Pump Voltage, Amps 120 V, 1.4 Amps
Control Board
Factory Installed. Freeze protection activates at 40°F and deactivates at
70°F. Thermostat connections. 60-second time delay for blower
activation. Pump timer circulates water for one minute every six hours
to prevent stagnation of water in the system. Boiler activation dry
contact. 24V AC isolation valve control.
Certifications ETL Listed
AH083P AH084P AH125P AH166P AH206P
Installation Indoor (approved for manufactured housing and mobile homes)
Suitable for Potable Water Systems Yes
Configurations
• Vertical: Upflow with bottom or side (left or right side) return
• Horizontal: Upflow with bottom return
Circulation Pump Included No
Product Weight - lb. (kg) (approximate) 57 (26) 57 (26) 57 (26) 62 (28) 74 (34)
Cabinet Construction
Embossed cabinet in heavy gauge galvanized steel to prevent
corrosion. Cabinet lined with 5/8 in. foil faced insulation.
Nominal CFM (Cubic Feet/Minute) 800 800 1,200 1,600 2,000
Nominal Output Btu/hr at 140°F
1
30,000 40,000 50,000 60,000 60,000
Rated Voltage 120 V, 60 Hz, 1 Ph
Transformer Size and Type 40 VA, Class 2
Blower Wheel (Diameter x Width) 9x6 in. 9x6 in. 10x8 in. 10x8 in. 10x10 in.
Blower Motor Type 3-Speed PSC
Blower Motor Hot Water Coil Rows 3 4 3
Coil Material Copper Coil, UV Resistant Pan
Blower Motor Horsepower (HP) 1/3 1/3 1/2 3/4 3/4
Blower Full Load Amps (FLA) 5.3 5.3 7.1 7.5 10.5
Water Connection 3/4 in. Sweat
Control Board
Factory Installed. Freeze protection activates at 40°F and deactivates at
70°F. Thermostat connections. 60-second time delay for blower
activation. Boiler activation dry contact. 24V AC isolation valve control.
Certifications ETL Listed