Spec Sheet

4
Rinnai products are continually being updated and improved; therefore, specifications are subject to change without
prior notice.
100000679
2/2020
1
Factory default setting for both heating and cooling.
Air Handler
Models
Speed
Air Flow (CFM) vs External Static Pressure (WC)
0.1 0.2 0.3 0.4 0.5
AH083P
AH083CP
Low 749 705 658 614 558
Med
1
865 815 760 708 646
High 904 836 801 740 681
AH084P
AH084CP
Low 749 705 658 614 558
Med
1
865 815 760 708 646
High 904 836 801 740 681
AH125P
AH125CP
Low 1198 1144 1086 1018 962
Med
1
1257 1198 1130 1072 1010
High 1273 1215 1158 1094 1018
AH166P
AH166CP
Low 1576 1514 1433 1338 1264
Med 1643 1576 1490 1407 1320
High
1
1707 1606 1545 1441 1364
AH206P
AH206CP
Low 1759 1691 1652 1580 1512
Med 1838 1788 1729 1644 1555
High
1
1928 1867 1810 1729 1637
Results are obtained while air handler is operating with a dry DX coil and air filter installed.
Values are nominal and blower performance can vary higher or lower from these values based on the
evaporator coil that is used. Hot water heat air flow performance data includes associated air pressure
drop across a four-row hot water coil for models AH084P/CP, AH125P/CP, and AH166P/CP, and air
pressure drop across a three-row hot water coil for models AH083P/CP and AH206P/CP.
Accessory Part #
Universal Air Handler Rack Assembly
AHRACK-1
Domestic Priority Switch
REU-OPU3
Pipe Cover Enclosure:
Pipe cover for HE+ Series (RL Non-Condensing) Tankless Water Heater Models
PCD03-SM2
Pipe cover for SENSEISE+ Series (RU Condensing) Tankless Water Heater
Models and I-Series (Condensing) Combi Boiler Models
PCD07-SM
Pipe cover for HE Series (V Non-Condensing) Tankless Water Heater Models
PCD03-EWV
24V NC Brass Solenoid Valve (3/4 in. NPT)
607000018
Heat Pump (HP) Lockout Kit 605000032