Spec Sheet
4 
Rinnai products are continually being updated and improved; therefore, specifications are subject to change without 
prior notice. 
100000679  
2/2020 
●
1
 Factory default setting for both heating and cooling.  
Air Handler 
Models 
Speed 
Air Flow (CFM) vs External Static Pressure (WC) 
0.1  0.2  0.3  0.4  0.5 
AH083P 
AH083CP 
Low  749  705  658  614  558 
Med
1
  865  815  760  708  646 
High  904  836  801  740  681 
AH084P 
AH084CP 
Low  749  705  658  614  558 
Med
1
  865  815  760  708  646 
High  904  836  801  740  681 
AH125P 
AH125CP 
Low  1198  1144  1086  1018  962 
Med
1
  1257  1198  1130  1072  1010 
High  1273  1215  1158  1094  1018 
AH166P 
AH166CP 
Low  1576  1514  1433  1338  1264 
Med  1643  1576  1490  1407  1320 
High
1
  1707  1606  1545  1441  1364 
AH206P 
AH206CP 
Low  1759  1691  1652  1580  1512 
Med  1838  1788  1729  1644  1555 
High
1
  1928  1867  1810  1729  1637 
•  Results are obtained while air handler is operating with a dry DX coil and air filter installed.  
•  Values are nominal and blower performance can vary higher or lower from these values based on the 
evaporator coil that is used. Hot water heat air flow performance data includes associated air pressure 
drop across a four-row hot water coil for models AH084P/CP, AH125P/CP, and AH166P/CP, and air 
pressure drop across a three-row hot water coil for models AH083P/CP and AH206P/CP. 
Accessory  Part # 
Universal Air Handler Rack Assembly  
AHRACK-1 
Domestic Priority Switch 
REU-OPU3 
Pipe Cover Enclosure:  
•  Pipe cover for HE+ Series (RL Non-Condensing) Tankless Water Heater Models 
PCD03-SM2 
•  Pipe cover for SENSEI™ SE+ Series (RU Condensing) Tankless Water Heater 
Models and I-Series (Condensing) Combi Boiler Models 
PCD07-SM 
•  Pipe cover for HE Series (V Non-Condensing) Tankless Water Heater Models  
PCD03-EWV  
24V NC Brass Solenoid Valve (3/4 in. NPT)  
607000018 
Heat Pump (HP) Lockout Kit  605000032 