AVENGER 25TRE CAPELLA 18TRE Unflued Room Heater Customer Operation & Installation Manual SET ON/OFF This appliance shall be installed in accordance with: Manufacturer’s Installation Instructions Local Gas Fitting Regulations Municipal Building Codes AG601/AS5601-2000 Gas Installations, AS/NZS 3000 Wiring Rules Any other relevant Statutory Regulation This appliance must be installed, serviced and removed by an Authorised Person Proudly a member of the AGA All of our gas products are AGA tested and approve
RINNAI GUARANTEE OF QUALITY As a purchaser of a high quality Rinnai product, we provide you with the following guarantee on your new Portable Convector Space Heater. Free Labour Period Free Parts Period FANS 5 Years 5 Years COMBUSTION CHAMBER 5 Years 10 Years Pro-Rata* ALL Other parts 5 Years 5 Years * Combustion chamber full replacement parts costs in the first 5 years, reducing 20% per year thereafter.
TABLE OF CONTENTS RINNAI GUARANTEE OF QUALITY ...........................................................................i ABOUT YOUR NEW AVENGER/CAPELLA TRE.......................................................1 CONTROL PANEL LAYOUT ......................................................................................2 REMOTE CONTROL ...................................................................................................3 FEATURES.................................................................
ABOUT YOUR NEW AVENGER/CAPELLA TRE Rinnai Australia 1 RCE-470/670 TRE
CONTROL PANEL LAYOUT Rinnai Australia 2 RCE-470/670 TRE
REMOTE CONTROL Rinnai Australia 3 RCE-470/670 TRE
FEATURES PUSH BUTTON IGNITION Only one touch of the STANDBY/ON switch is required to operate the heater. CHILD LOCK When the Child Lock is activated all controls other than the STANDBY/ON switch will be locked. Deactivating the lock releases the controls. If the lock is activated when the appliance is in STANDBY, all functions will be locked.
IMPORTANT POINTS Unpacking Appliance: Check for damage. If the heater is damaged, contact your supplier for advice. Before installing the appliance, check it is labelled for the correct gas type (see label on rear of heater). Refer to local gas authority for confirmation of gas type if you are in doubt. The following items should also be included in the carton: Customers Operation Information, Remote Control, Remote Control Caddy and Batteries. IMPORTANT 1.
IMPORTANT POINTS Do not allow children to post articles in the louvres. The appliance is not intended for use by young children or infirm persons without supervision. SET O N/O FF SET O N/ OFF Young children should be supervised to ensure they DO NOT play with the appliance. Do not allow children or elderly persons to sleep in the warm air discharge from the heater. SET O N/O FF Do not cover or place articles on this heater. Ventilate the room when this heater is in use.
IMPORTANT POINTS Do not operate/install this heater in areas where painting is taking place, or in places such as hairdressing salons, where there may be fluff and dust, and where aerosols are used. SET O N / OF F Turn the heater on to STANDBY after use. Keep heater away from flammable materials. Combustible materials must not be placed where the heater could ignite them. SET O N/O FF Do not spray aerosols near this heater while it is in use.
IMPORTANT POINTS Do not place articles in front of the louvres. SET ON/OFF Do not move the heater whilst it is turned on. SET ON/OFF Do not unplug the heater while it is in operation or while the fans are still cycling. SET ON/OFF Unplugging the heater will cause the timer and clock to stop, however programmed ON/ OFF times will remain in the memory. Do not place containers of liquid on top of the heater.
IMPORTANT POINTS A dedicated 240V 10 Amp power point must be used with this appliance. Do not use power boards or double adaptors to operate this appliance. Heater must not be located below a power socket-outlet. Heat emanating from the front of this appliance may over time affect the apperance of some materials used for flooring such as carpet, vinyl, cork or timber. This effect may be amplified if the air in the room contains cooking vapours or cigarette smoke.
CUSTOMER OPERATING INSTRUCTIONS Specifications: See back cover of this instruction. UNPACKING Never lift the heater out of the carton by top louvres. Check for damage, if unit is damaged contact supplier or Rinnai for advice. BEFORE USING THE HEATER Check unit supplied is correct for gas type in your area. Refer to local Gas Authority for confirmation of gas type if in doubt.
HOW TO OPERATE THE HEATER Rinnai Australia 11 RCE-470/670 TRE
ADJUSTING TEMPERATURES Rinnai Australia 12 RCE-470/670 TRE
HEATER MODES & FUNCTIONS Your appliance has several "MODE" settings to choose from. The factory default setting is "GAS". For your convenience in normal operation the appliance’s memory will select the "MODE" that was last used. COMFORT AND ECONOMY As a room is warmed, the walls and ceilings are also warmed, making one feel a little warmer than when the ceilings and walls were cold, even though the room temperature is the same.
SETTING HEATER MODES Rinnai Australia 14 RCE-470/670 TRE
SETTING CLOCK Rinnai Australia 15 RCE-470/670 TRE
PROGRAMMING THE ON/OFF TIMERS Here we will learn how to set the Timer (s) function by following the steps below.
OPERATING THE ON/OFF TIMERS Now that the timer (s) functions have been programmed they can operated as follows. PRE-HEAT This function operates automatically in conjunction with the Timers. When a Timer is selected, the heater may operate anywhere within an hour prior to the programmed starting time of a Timer. This function is called Pre-heat since it ensures the room reaches the desired temperature by the time the Timer programs ON time.
OVERIDE FUNCTION USING THE REMOTE CONTROL Rinnai Australia 18 RCE-470/670 TRE
CHILD LOCK SAFETY DEVICES OVER HEAT SWITCH When the heater gets too hot during operation (for example when the filters or air outlet louvres are blocked) this device turns the gas and or electric heating element off automatically. Remove cause of overheat (clean filters) allow heater to cool, then re-ignite. FUSE The electrical circuits are protected by a fuse. When the fuse blows, the heater will not operate at all. The fuse must be replaced by an authorised person.
CARE OF HEATER Your heater needs very little maintenance, but the following information will help you to keep it looking good, and working efficiently. Unplug before cleaning. All parts of the heater can be cleaned using a soft, damp cloth. Do not use solvents to clean any parts. Do not spray aerosols in the vicinity of the heater whilst in operation. Do not place articles on or against this heater. Do not store flammable materials near this heater.
FAULT FINDING Please note: Service calls for general cleaning, maintenance and wear and tear are not necessarily covered under the guarantee. Service calls of this nature may be chargeable. SERVICE Rinnai recommend that this appliance be serviced every 2 years. If the power supply cord, gas supply hose or any other component of the heater is damaged, they must be replaced by Rinnai or a suitably qualified person. Any service or repair work should only be carried out by an authorized person.
ERROR CODES Your appliance has the ability to check its own operation continuously. If a fault occurs an Error Code will flash on the digital display of the control panel. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please quote the Error Code displayed when enquiring about service.
SPECIFICATIONS DIMENSIONS Dimensions in mm 202 610 570 203 243 Rinnai Australia 23 RCE-470/670 TRE
SPECIFICATIONS WIRING DIAGRAM CONTROL DISPLAY UNIT r bl bl bl bl bl bl bl bl bl THERMOCOUPLE OUTPUT CHECK TERMINAL 1 2 3 4 5 6 7 8 9 10 RCR 1 2 3 r w w SW1 OH.TH w w 1 2 or gy y br w bk 1 2 bk bk 1 2 3 4 5 6 7 8 9 10 bl y bk bk bl w y w w r 1 2 3 4 y r bl br 1 2 3 4 5 6 TH ODS2 OH.TH ODS1 TF MARK PART NAME TH THERMISTOR TF THERMAL FUSE F FUSE CFM CONVECTION FAN MOTOR HFM HEATER FAN MOTOR ER ELECTRODE POV MODULATING SOLENOID VALVE TR TRANSFORMER OH.
NOTES Rinnai Australia 25 RCE-470/670 TRE
CUSTOMER CONTACTS Internet: Email: www.rinnai.com.au enquiry@rinnai.com.au Head Office, Australia 10-11 Walker Street, Braeside, VIC 3195 Tel: (03) 9271 6625 Fax: (03) 9271 6622 State Offices New South Wales Western Australia 62 Elizabeth Street, Wetherill Park NSW 2164 18 Belgravia Street, Belmont, WA 6104 Product Sales Vic / S.A. / N.T. / Tas New South Wales / A.C.T.