Portable Unflued Gas Convection Heater Operation Manual To Suit Models Avenger 25 Blaze 21 Dynamo 15 Enduro 13 This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Local Regulations and Municipal Building Codes This appliance must be serviced and repaired by an Authorised Person. All Rinnai gas products are A.G.A. certified.
Rinnai Australia Operation Manual
TABLE OF CONTENTS RINNAI WARRANTY ............................................................................................................... ii ABOUT YOUR PORTABLE CONVECTOR HEATER............................................................. 1 GENERAL DESIGN LAYOUT............................................................................................................ 1 NAVIGATING THE CONTROL PANEL .............................................................................................
RINNAI WARRANTY WARRANTY TERMS The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which you have under the Trade Practices Act and similar State or Territory Laws.
ABOUT YOUR PORTABLE CONVECTOR HEATER GENERAL DESIGN LAYOUT 2 1 4 5 4 3 8 5 7 9 11 AVENGER BLAZE 10 5 2 1 4 8 4 7 3 9 11 10 DYNAMO 5 2 1 4 8 4 7 9 11 ENDURO 10 1 Control panel 6 Gas inlet connection 2 ON / OFF button Stops and operates the heater.
ABOUT YOUR PORTABLE CONVECTOR HEATER NAVIGATING THE CONTROL PANEL 28 22 24 26 30 29 19 Avenger Blaze Dynamo 27 21 25 38 36 13 16 14 15 28 2 18 23 20 17 32 30 12 29 Enduro 2 27 37 35 31 34 13 33 12 On / Combustion indicator When GREEN appliance is in standby, when RED the burner is operating and when flashing RED there is a fault. 12 26 Override indicator Indicates the Override function is in operation. 27 Economy button Operates the Economy mode.
ABOUT YOUR PORTABLE CONVECTOR HEATER NAVIGATING THE REMOTE CONTROL 42 39 ON button Operates the heater. 40 OFF button Stops the heater. 41 Up and Down buttons Used to raise or lower the set temperature. 42 Infra red transmitter Transmits signal to heater. 43 Battery The remote control is powered by one CR2032 3V battery. To replace the battery simply slide open the battery cradle cover located on the back of the remote control.
FEATURES FEATURES COMMON TO ALL MODELS PUSH BUTTON IGNITION Only one touch of the STANDBY/ON switch is required to operate the heater. CHILD LOCK When the Child Lock is activated all controls other than the STANDBY/ON switch will be locked. Deactivating the lock releases the controls. If the lock is activated when the appliance is in STANDBY, all functions will be locked. FILTER INDICATOR When the fan filters become covered with dust, the filter indicator will flash.
IMPORTANT POINTS The appliance is not intended for use by young children or infirm persons without supervision. Young children should always be supervised to ensure that they DO NOT play with the appliance. DO NOT allow children or elderly persons to sleep in the warm air discharge from the heater.DO NOT sit on this heater . DO NOT post or allow children to post articles into the louvres of the heater. DO NOT cover or place articles on this heater. DO NOT place articles in front of the louvres .
IMPORTANT POINTS It is recommended that a dedicated 240V 10 Amp power point be used with this appliance. DO NOT use power boards or double adaptors to operate this appliance. Heater MUST NOT be located below a power socket-outlet DO NOT place containers of liquid on top of the heater. Water spillage can cause extensive damage to the appliance and create an electrocution hazard. . When the heater is unplugged the for an extended period the clock will stop and will need to be reset.
INSTALLATION UNPACKING THE APPLIANCE Check for damage. If the heater is damaged, DO NOT INSTALL and contact your supplier for advice. WHAT’S IN THE BOX The following items should also be included in the carton: This Operation Manual and Remote Control with Battery. BEFORE INSTALLING THE APPLIANCE • Check it is labelled for the correct gas type (see label on rear of heater).
INSTALLATION CHECKING ROOM SIZE The heaters MUST NOT be installed in a room smaller than specified, these are: The Avenger 25 minimum room size 62.5 m³. The Blaze 21 minimum room size 52.5 m³. The Dynamo 15 minimum room size 37.5 m³. The Enduro 13 minimum room size 32.5 m³. Height To determine if the intended room meets the minimum size requirements simply multiply the Height x Width x Depth. For example if the room dimensions are Length 5.3 metres, Width 5.0 metres and Height 2.
HOW TO OPERATE THE HEATER 39 ON OFF 40 Avenger Blaze Dynamo 41 2 15 17 13 Enduro 12 2 33 31 13 12 TO TURN THE HEATER ON Before you begin, ensure that the Gas and Power have been connected correctly to the appliance. To turn the appliance on press the ON/OFF button 2 located on the control panel. For models that are equipped with a remote control the ON button 39 may also be used.
HOW TO OPERATE THE HEATER 39 ON OFF 40 Avenger Blaze Dynamo 41 2 28 27 15 17 13 Enduro 12 2 28 33 27 31 13 12 TO TURN THE HEATER OFF To turn the heater off while it is in operation press the ON/OFF button 2 located on the control panel. For models that are equipped with a remote control the OFF button 40 may also be used. The On/Combustion indicator NOTE 12 will go out. After the On/Combustion indicator 12 has gone out, the appliance fan will continue to cycle for several minutes.
TIMER OPERATION - AVENGER, BLAZE & DYNAMO CLOCK AND DUAL TIMERS The setting of the Clock and programming of the Timers is done via the Set Times button 18 . Each press of this button will cycle the appliance through the available clock setting and timer programming modes that are available. CHECKING THE CLOCK 18 One press of the Set Times button time that the clock is set to.
TIMER OPERATION - AVENGER, BLAZE & DYNAMO PROGRAMMING TIMER 2 Five presses of the Set Times button 18 selects the Timer 2 ‘On’ programming mode which allows adjustment of the time when the heater switches ‘On’ (or starts). The Timer 2 and On indicators 20 are illuminated. The factory default Timer 2 ‘On’ time is AM 06:00. Press the Up or Down buttons 13 to adjust the Timer 2 ‘On’ time.
TIMER OPERATION - AVENGER, BLAZE & DYNAMO PREHEAT This function operates automatically in conjunction with the Timers. When a Timer is selected, the heater may operate anywhere within an hour prior to the programmed starting time of a Timer. This function is called Pre-heat since it ensures the room reaches the desired temperature by the On Time programmed into the Timer(s). The room temperature is sensed one hour before the programmed On Time.
TIMER OPERATION - ENDURO OPERATING THE ON TIMER The Delay On Timer allows you to delay the start time of the heater for up to 24 hours. 36 2 35 31 34 13 12 To operate, press the On Timer button 35 . The On Timer indicator 36 will illuminate and the Combustion indicator 12 will be illuminated green to confirm that the heater is awaiting for the Delay ‘on’ time period to pass before commencing operation.
LOCK AND SAFETY DEVICES USING THE LOCK FUNCTION 29 The Lock function will avoid accidental operation and prevent small children from altering the heater settings. To Activate the Lock To activate the Lock function press both the Up and Down buttons 13 simultaneously for 3 seconds. The function is activated immediately and the Lock indicator 29 will be illuminated. 13 12 29 To Deactivate the Lock To deactivate the Lock function press both the Up and Down buttons 13 simultaneously for 3 seconds.
CARE AND MAINTENANCE Your heater needs very little maintenance, but the following information will help you to keep it looking good and working efficiently. Unplug before cleaning. IMPORTANT All parts of the heater can be cleaned using a soft, damp cloth. DO NOT use solvents to clean any parts. DO NOT spray aerosols in the vicinity of the heater whilst in operation. DO NOT place articles on or against this heater. DO NOT store flammable materials near this heater.
CARE AND MAINTENANCE TROUBLE SHOOTING CHECKLIST Not plugged in or turned off. Mains power failure. (Initial Install) Air in gas pipe. Air in hose Room too large Dust on air filters Louvre obstructed Air filter blocked Gas escape Gas supply turned off. Lock set. On Timer is set. Flat batteries.
SPECIFICATIONS GENERAL SPECIFICATIONS General Description: Portable Gas Convector Heaters. Gas Control: Electronic control Burner Surface Combustion Burner Gas Connection: 3/8” MI BSP into 1.
Rinnai Australia 19 Operation Manual
CONTACT INFORMATION Australia Pty. Ltd. Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au ABN 74 005 138 769 Head Office National Help Lines 10-11 Walker Street, Braeside, Victoria 3195 P.O. Box 460 Tel: (03) 9271 6625 Fax: (03) 9271 6622 Sales & Service Tel: 1300 555 545* Fax: 1300 555 655* Spare Parts & Technical Info Tel: 1300 366 388* Fax: 1300 300 141* *Cost of a local call Higher from mobile or public phones.