SYSTEM MENU 
The system menu allows to modify the following 
parameters: 
Parameter  Description 
AC/HP 
TONS 
Allows you to specify the tonnage of 
the outdoor unit. 
CFM/TON 
Allows you to set a precise CFM per 
TON ratio. 
DEHUM 
ON STATE 
Defines if the dehumidification will 
be active-high or active-low. 
DEHUM  
RATIO 
Allows you to modify the  
percentage of the cooling CFM that 
will be delivered when  
dehumidification is active. 
AC Y1  
RATIO 
Allows you to modify the  
percentage of the cooling CFM that 
will be delivered when only a first 
stage call for cooling (Y1) is active. 
Parameter  Description 
AC/HP ON  This parameter allows to set the wait 
time before the fan starts when a call 
is made on Y1 or Y2. 
AC/HP 
OFF 
This parameter allows to set the time 
the fan will keep running after the end 
of a call on Y1 or Y2. 
HEAT ON  This parameter allows to set the wait 
time before the fan starts when a 
heating call is made on W1 or W2. 
HEAT 
OFF 
This parameter allows to set the time 
the fan will keep running after the end 
of a call on W1 or W2. 
COOLING / HP MENU 
The Cooling / HP menu allows to modify the  
options regarding the behavior with an outdoor 
unit. 
DELAYS MENU 
This menu allows to adjust timing parameters of 
the unit. 
Parameter  Description 
FURNACE 
MODEL 
This parameter allows to manually 
select the model of the unit. This pa-
rameter must be used when the con-
trol board is replaced. This is to be 
set as CAH050E. 
RESET 
SYSTEM 
Reinitialize all the user modifiable 
parameters to their factory default. 