Installation Manual
Canadian Air Handler Installation and Operation Manual   5 
The hydronic air handler is designed to work 
with Rinnai tankless water heaters and boilers 
(models listed below) to deliver a wide variety 
of heating capacities for residential and light 
commercial applications.  
The hydronic air handler works with the following 
Rinnai products:  
•  Rinnai Tankless Water Heaters:  
−  SENSEI™ SE+ Series  
(RU Condensing Models) 
It is the responsibility of the installer to follow all 
national codes, standards and local ordinances, 
in addition to the instructions in this manual. The 
installation must comply with regulations of the 
local building, heating, plumbing, and other 
codes. Where local codes are not applicable, the 
installation must comply with the national codes 
and all authorities having jurisdiction. 
The following is a suggested list of codes and 
standards for the United States and Canada: 
General Installation 
•  Installation of Air Conditioning and 
Ventilating Systems NFPA 91 (latest edition) 
•  CSA B214-01 Installation Code for Hydronic 
Heating Systems 
Duct Systems 
•  Sheet Metal and Air Conditioning 
Contractors National Association (SMACNA) 
•  American Society of Heating, Refrigeration, 
and Air Conditioning Engineers (ASHRAE)   
•  2001 Fundamentals Handbook Chapter 34 
or 2000 HVAC Systems and Equipment 
Handbook Chapters 9 and 16 
•  US and CANADA: Air Conditioning 
Contractors Association (ACCA) Manual D 
Acoustical Lining and Fibrous Glass Duct 
•  US and CANADA: Current edition of 
SMACNA; NFPA 90B as tested by UL 
Standard 181 for Class I Rigid Air Ducts 
Electrical Connections 
•  US: National Electrical Code (NEC) ANSI/
NFPA 70 (latest edition) 
•  CANADA: Canadian Electrical Code CSA 
C22.1 (latest edition) 
Plumbing Systems 
•  US and CANADA: ICC International 
Plumbing Code (IPC); Uniform Mechanical 
Code (UMC); Uniform Plumbing Code 
(UPC), National Plumbing Code (NPC) 
Refer to section “3.7 Specifications” for a 
complete list of product specifications.  
            NOTE 
            NOTE 
Tankless water heaters must have a 
minimum input rate of 160,000 Btu/hr.  
RUR condensing model water heaters 
are not approved for use with this is air 
handler.  
•  Rinnai Boilers: 
−  I-Series (Condensing) Combi Models 
If utilizing a boiler, ensure the output of 
the boiler exceeds the capacity of the 
air handler in use (the boiler Btu/hr 
rating must be greater than the air 
handler Btu/hr rating). 