Installation Guide
64 Rinnai Tankless Water Heater Installation and Operation Manual
Rinnai CX Tankless Water Heaters include Circ-Logic technology that offers the comfort and
convenience of instant hot water with the use of an external recirculation pump. Circ-Logic controls
the on/off sequence and operation cycles of the external recirculation pump through the
programming of the tankless water heater’s parameter settings. Smart-Circ™ is the factory default
setting for recirculation. Smart-Circ™ allows the water heater to identify when hot water is used, and
then operates recirculation on subsequent days to reduce wait time for hot water. If a fixed
recirculation schedule is desired, then installation of an MC-195T-US Timer/controller or Wi-Fi
Module is required.
With residential units, the external pump cable is not included with the tankless water heater and
must be purchased separately. Circ-Logic operates in either Economy or Comfort mode based on
the parameter settings of the water heater.
• Economy Mode - Cycles the pump less often, using less energy to maintain the circulation loop
temperature.
• Comfort Mode - Cycles the pump more frequently, ensuring the loop temperature remains higher
(but also uses more energy).
Note: Rinnai offers an Internal Add-on Recirculation Conversion Kit (part number: RX2RXPCK) to
convert a no pump model to a pump model.
Rinnai Set Temperature
140 135 130 125 120 115 110 108 106 104 102 100 98
Parameter
Setting 01A
140 135 130 125 120 115 110 145 150 155 160 165 170 175 180 185
Parameter
Setting 01b
Typical Pump OFF Intervals (Minutes)
Economy
18 20 22 24 28 32 38 40 44 48 52 56 62 18 18 18 18 18 18 18 18 18
Comfort
9 10 11 12 14 16 19 20 22 24 26 28 31 9 9 9 9 9 9 9 9 9
Table 28
Components
within dashed
line are inside
water heater
FUSE
B
R
G
External
Pump
Harness:
Rinnai Part #:
105000250
Connect Ground (GN)
Wire to tankless housing
B
W
Figure 71
EXTERNAL
PUMP