Installation Guide
Rinnai Tankless Water Heater Installation and Operation Manual 73
Table 31. Performance Data Table
* Refer to the following tables for additional information:
# Data Unit
0 1
Water Flow Rate x0.1 gal/min
02
Outgoing Temperature °F
03
Combustion Hours x100 Hours
04
Combustion Cycles *
05
Fan Frequency Hz
06
Additional Controllers Connected *
07
Water Flow Control Position 0=Mid 1=Open 2=Closed
08
Inlet Temperature °F
09
Fan Current x10 mA
10
Total Bath Fill Amount Gallons
1 1
HEX Outlet Temp. °F
12
Bypass Flow Control Position Degrees of opening
17
Freeze Protection Temperature °F
19
Pump Hours x100 Hours
20
Pump Cycles *
2 1
Exhaust Temperature °F
22
Pump Frequency Hz
23
Lime Detecting Temperature °F
24
Descaling Cycles
DISPLAY CYCLE COUNT
000 to 999
x100 (0 to 99,900)
10– to 99-
x10,000 (100,000 to 990,000)
1-- to 6--
x1,000,000 (1,000,000 to 6,000,000)
CONTROLLER MODEL CONNECTED NOT CONNECTED
MC
__1 __0
BC
_1_ _0_
BSC & BSC2
1__, 2__ (QTY2) 0__
Default display is 100.
_ depends on connection status of another controller.
06
Controllers Connected
04
Combustion Cycles
20
Pump Cycles