GAS DRYER Dry-Soft 4 & 6 ® Operation / Installation Manual Models: RD-400AU & RD-600AU This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000, AS/NZS 3500 & AS 5601 • Local Regulations and Municipal Building Codes This appliance must be installed, serviced and removed by an Authorised Person. All Rinnai gas products are A.G.A. certified.
REGULATORY INFORMATION This appliance must be installed, commissioned and serviced by an Authorised person in accordance with local gas, electrical and plumbing regulations. The installation must also comply with these instructions. The appliances referred to in this manual have been certified by the Australian Gas Association (AGA). The AGA Certification number is shown on the appliance dataplate. Keep this manual in a safe place for future reference.
OPERATION MANUAL REGULATORY INFORMATION...................................................................................i WARRANTY .................................................................................................................i ABOUT YOUR DRY-SOFT GAS DRYER ...................................................................1 CONTROL PANEL NAVIGATION ................................................................................................ 1 OVERVIEW OF APPLIANCE ...................
ABOUT YOUR DRY-SOFT GAS DRYER CONTROL PANEL NAVIGATION 15 14 CLEAN FILTER GENERAL 7 11 OPERATING EXTRA SOFT 9 12 FINISH THICK 8 13 TIMER DELICATE 4 5 6 1 2 10 3 1 ON / OFF BUTTON Turn ‘ON’ and ‘OFF’ the electric power supply to the appliance. 2 START/PAUSE BUTTON Start and pause the drying function. 3 PROGRAM BUTTON Select the drying programme. 4 TIMER BUTTON Select operation in Timer mode. 5 ’UP’ BUTTON Increase the drying time (operation in Timer mode only).
ABOUT YOUR DRY-SOFT GAS DRYER OVERVIEW OF APPLIANCE Rinnai 2 Dry-Soft® RD-400/600AU Operation Manual
SAFETY INFORMATION DO NOT OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTION BOOKLET. DO NOT PLACE ARTICLES ON OR AGAINST THISAPPLIANCE. DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS, OR SPRAY AEROSOLS NEAR THIS APPLIANCE. DO NOT OPERATE WITH PANELS, COVERS OR GUARDS REMOVED FROM THIS APPLIANCE. DO NOT LOAD MATERIALS CONTAINING FLAMMABLE SOLVENTS INTO THIS APPLIANCE WARNING Rinnai • Ensure all articles are removed from pockets. These include flammable items such as matches and cigarette lighters.
FEATURES AND BENEFITS 1. Quick Drying - The range of Rinnai gas clothes dryers utilise gas as the drying medium rather than electricity. This results in a considerable reduction in drying time when compared to most electric clothes dryers. 2. Economical - The range of Rinnai gas clothes dryers are highly efficient. In addition, they utilise gas rather than electricity as the drying medium.
OPERATION ITEMS UNSUITABLE FOR TUMBLE DRYING • Do not tumble dry fabrics if the care label states that tumble drying is not suitable. These may include items made from silk, wool, wool blends, leather, lace or hemp. These fabrics may shrink, deform or fade. The same applies to items with printing or glued emblems which may fade or separate.
OPERATION OPERATION IN AUTOMATIC MODE 1. Open the dryer door and place items selected for drying evenly into the dryer drum. Close the dryer door and press the 'On/Off' button 1 . The default drying programme is set to GENERAL 7 + EXTRA SOFT 9 and these mode indicators will be illuminated. 2. To select an alternative drying programme press the 'Programme' button 3 until the desired mode indicator illuminates.
CARE AND MAINTENANCE CLEANING THE LINT FILTER The lint filter should be cleaned after every drying cycle. Regular cleaning is important to maintain drying efficiency. The 'CLEAN FILTER' indicator 14 illuminates when the lint filter is too blocked and requires cleaning. A alarm will also sound after operation stops for 5 minutes or until the dryer door is opened, whichever comes first.
CARE AND MAINTENANCE CLEANING THE AIR INLET FILTER 8 The air inlet filter is located at the bottom of the appliance. Pull it out as shown. 9 Remove any dust from the air filter by using your hands, a soft cloth or a soft brush as shown. If removal of the lint proves difficult, the air filter may also be cleaned with the assistance of COLD water and a soft cloth or brush. 10 After removing dust, re-insert the air inlet filter.
TROUBLE SHOOTING TROUBLE SHOOTING CHECK LIST Please check the following list before calling for Service. Service calls may be charged if faults are caused by operation errors. Refer to the Warranty Conditions for more details. If the dryer does not operate at all, check to see if the digital display is flashing with two numbers. If yes, refer to “ERROR CODES” on page 10.
TROUBLE SHOOTING ERROR CODES Rinnai Dry-Soft gas clothes dryers have a self diagnostic function. If a fault occurs, a 2 digit code will flash on the Digital Display 15 on the control panel. This assists with diagnosing the fault and may enable a problem to be solved without the need for attendance by service personnel. Please quote the code displayed when arranging a service call.
INSTALLATION MANUAL SPECIFICATIONS ...................................................................................................12 POSITIONING OF THE APPLIANCE ......................................................................13 GAS CONNECTION AND SUPPLY .........................................................................13 ELECTRICAL SUPPLY ............................................................................................14 APPLIANCE MOUNTING OPTIONS ...............................
INSTALLATION SPECIFICATIONS Description: Rinnai Gas Dryer - Dry-Soft® 4 Rinnai Gas Dryer - Dry-Soft® 6 RD-400AU RD-600AU Dimensions (mm) Height: 609, Width: 550, Depth: 490 Height: 684, Width: 650, Depth: 530 Gas Consumption 13 MJ/h 16.5 MJ/h Model: Natural Propane Natural Propane 1.13 / 2.75 2.75 1.13 / 2.75 2.75 Gas Supply Pressure (kPa) Weight: (Body only) 27.0 kg 32.
INSTALLATION This appliance shall be installed in accordance with: IMPORTANT • Manufacturers’ Installation Instructions • Local gas fitting regulations • Municipal building codes • AS 5601 Gas Installations and AS/NZS 3000 Wiring Rules • Any other relevant Statutory Regulations This appliance must be installed, serviced and removed by an Authorised Person. POSITIONING OF THE APPLIANCE The main considerations when positioning the dryer are: • Ensuring all minimum clearance requirements as shown are met.
INSTALLATION ELECTRICAL SUPPLY This appliance is supplied with a 1.5 metre long power cord with a three pin plug. Rinnai recommends that the dryer be plugged into a dedicated 240V, 10A earthed power point. Alternatively the appliance can be direct wired if the power supply is to be concealed. IMPORTANT Consult a qualified electrician if direct wiring is required as it must comply with the requirements of AS 5601, AS 3000 and any other relevant local regulations.
INSTALLATION WALL MOUNTING BRACKET ASSEMBLY The wall mounting bracket is provided in kit form with the following components: 1 x Wall Fame 1 x Support Frame 4 x Hex Head Bolts and Washers 4 x Mounting Screws and Washers Some minor assembly is required before the wall mounting bracket can be fixed to the wall. To assemble the wall mounting bracket use the four hex head bolts and washers provided and securely attach the support frame to the wall frame.
INSTALLATION SWAPPING DOOR FROM LEFT TO RIGHT OPENING The dryer access door may be swapped from a left handed opening as supplied from the factory to a right handed opening. When changing door opening direction ensure the appropriate clearances are provided. Refer to “POSITIONING OF THE APPLIANCE” on page 13 for clearance details. 1 Open the dryer door fully so that it locks in the open position. 2 Remove the two plastic tabs from the appliance body to reveal the right hand door hinge attachment points.
INSTALLATION EXHAUST DUCT Rinnai gas dryers must be installed with Rinnai gas dryer exhaust duct components. Two exhaust duct kits are available, DFVKIT - vertical exhaust kit and DSHKIT horizontal exhaust duct kit. Each kit consists of rigid aluminium pipes (can be cut to length as required) and vertical or horizontal terminals, stand-off brackets, rigid bends and an internal wall plate.
INSTALLATION EXHAUST DUCT SYSTEM COMPONENTS: A DSFSPIGOT Appliance adapter spigot (supplied with appliance). B DSFPIPE1000 Duct pipe 1000mm and stand-off clip (installed length 950mm, can be cut to length as required C DSVCOWL Vertical roof terminal 1060mm and stand-off clip (installed length to exhaust outlet 900mm). D DSFBEND Pair of 45° elbows. E DSFPLATE Internal wall plate. F DSHCOWL Horizontal wall terminal. G VENT Air vent, provides an open area of 250 cm² (x 2).
INSTALLATION EXHAUST DUCT INSTALLATION OPTIONS Following are the four most common exhaust duct installation methods. The exhaust duct length can be up to 8 metres long with a maximum of two 90° bends: i ii iii iv a C C c C e e e B B D b e B D e b e D D D D e B E E B D A f D b d F G i Direct Vertical. ii Offset Vertical. iii Extended Vertical. B iv Direct or Extended Horizontal. a Minimum clearance 500mm to nearest part of roof.
APPLIANCE DETAILS For future reference please take a moment to complete the following information: Your Retailer: Name: Installation Address: Telephone No.
CONTACT INFORMATION Australia Pty. Ltd. Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au ABN 74 005 138 769 Head Office National Help Lines Sales & Service Tel: 1300 555 545* 10-11 Walker Street, Braeside, Victoria 3195 P.O.