Brochure

Learn more at rinnai.us
VENT-FREE FAN CONVECTORS
FC510 (RCE-391A-H) FC824 (RCE-691TA-H)
OFF-WHITE OFF-WHITE
N G LP N G LP
5,500 /
10,000
5,600/
10,000
8,400/
24,000
8,000/
22,000
19.2 X 19.4 X 9.6
(487.6 X 492.7 X 243.8)
24 X 19 X 9.4
(609.6 X 482.6 X 238.76)
19 WATTS 29 WATTS
28 – 38 30-44
3 YEARS ON PARTS
5,200 5,200
N/A N/A
MODEL CHART AND SPECIFICATIONS
VENT-FREE CONVECTORS
ENERGYSAVER
®
DIRECT VENT WALL FURNACES
MODEL
EX08CT (RHFE-202FTA) EX11CT (RHFE-265FTA) EX17CT (RHFE-434FTA)
EX22CT (RHFE-559FTA) /
EX22CTW (RHFE-559FTA-W)
EX38CT (RHFE-1005FTA) /
EX38CTW (RHFE-1005FTA-W)
COLOR
BEIGE BEIGE BEIGE BEIGE BEIGE/WHITE
GAS TYPE
N G LP N G LP N G LP N G LP N G LP
INPUT RANGE (BTU)
(LOW/HIGH)
3,000 / 8,000
5,500 /
11,000
5,700 /
11,000
8,200 / 16,700
8,200 /
21,500
8,200 /
20,700
13,200 /
38,400
13,200 /
36,500
DIMENSIONS (W,H,D)
(mm)
18.3 X 27.4 X 10.1
(464.8 X 695.96 X 256.54)
18.3 X 27.4 X 10.1
(464.8 X 695.96 X 256.54)
29.9 X 22.9 X 10.1
(759.4 X 581.6 X 256.54)
29.9 X 22.9 X 10.1
(759.4 X 581.6 X 256.54)
36.6 X 26.4 X 13
(929.6 X 670.5 X 330.2)
POWER CONSUMPTION
(ELECTRONIC IGNITION)
41 WATTS 44 WATTS 46 WATTS 56 WATTS 117 WATTS
NOISE LEVEL dB(A)
27 – 36 31 - 38 33 - 38 33 - 42 39 – 46
WARRANTY*
10 YEAR HEAT EXCHANGER, FIVE YEARS ON PARTS, 2 YEARS ON LABOR
ALTITUDE APPROVED
(FT)
10,200
VENTING OPTION
CONCENTRIC
MODEL CHART AND SPECIFICATIONS
DIRECT VENT WALL FURNACES
VENT-FREE FAN CONVECTOR AND DIRECT VENT SELECTION GUIDE
ROOM VOLUME / HEATING AREA SIZE
BTU ZONE MODEL CUBIC FEET SQUARE FEET*
I
FC510
UP TO 5,400 UP TO 680
FC824
5,401 - 13,000 681 - 1,600
EX08CT
UP TO 3,500 UP TO 440
EX11CT
3,501 - 4,800 441 - 600
EX17CT
4,801 - 7,300 601 - 910
EX22CT
7,301 - 9,400 911 - 1,180
EX38CT
9,401 - 16,600 1,181 - 2,080
II
FC510
UP TO 4,500 UP TO 560
FC824
4,501 - 10,900 561 - 1,400
EX08CT
UP TO 3,000 UP TO 380
EX11CT
3,001 - 4,100 381 - 510
EX17CT
4,101 - 6,100 511 - 760
EX22CT
6,101 - 7,900 761 - 990
EX38CT
7,901 - 14,000 991 - 1,750
III
FC510
UP TO 3,800 UP TO 480
FC824
3,801 - 9,200 481 - 1,200
EX08CT
UP TO 2,500 UP TO 310
EX11CT
2,501 - 3,400 311 - 430
EX17CT
3,401 - 5,200 431 - 650
EX22CT
5,201 - 6,700 651 - 840
EX38CT
6,701 - 11,800 841 - 1,480
IV
FC510
UP TO 3,200 UP TO 400
FC824
3,201 - 7,600 401 - 1,000
EX08CT
UP TO 2,100 UP TO 260
EX11CT
2,101 - 2,800 261 - 350
EX17CT
2,801 - 4,300 351 - 540
EX22CT
4,301 - 5,500 541 - 690
EX38CT
5,501 - 9,800 691 - 1,230
V**
FC510
UP TO 2,600 UP TO 330
FC824
2,601 - 6,200 331 - 800
EX08CT
UP TO 1,700 UP TO 210
EX11CT
1,701 - 2,300 211 - 290
EX17CT
2,301 - 3,500 291 - 440
EX22CT
3,501 - 4,500 441 - 560
EX38CT
4,501 - 8,000 561 - 1,000
VI
FC510
UP TO 4,500 UP TO 560
FC824
4,501 - 10,900 561 - 1,400
EX08CT
UP TO 3,000 UP TO 380
EX11CT
3,001 - 4,100 381 - 510
EX17CT
4,101 - 6,100 511 - 760
EX22CT
6,101 - 7,900 761 - 990
EX38CT
7,901 - 14,000 991 - 1,750
*For complete information and details regarding Rinnai’s warranty, please visit rinnai.us.
I
II
II
III
IV
VI
V
V
Learn more at rinnai.us
11
SPECIFICATIONS
Chart should not be used as the sole document for making final product selection. Consult
with your Rinnai independent dealer. The guidelines apply to average house construction.
This is intended to be used as a guide and not a replacement for a professionally
engineered project.
Rinnai has not been to the location so this guidance is for your assistance only and should
not be the sole factor in making a sizing selection.
• Sizing does not describe a complete system.
The contractor/engineer must determine the necessary components for and configuration
of the particular system being installed.
Sizing does not imply compliance with local building codes.
It is the responsibility of the engineer/contractor to ensure the installation is in accordance with
all local building codes.
Confer with local building officials before installation.
RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability
for damages arising from information provided herein to or by consumers or third parties or for
damages arising from or associated with water quality, compliance with local codes, installation
methods, materials or other circumstances related to application or installation.
• Chart is to be used for supplemental heat applications only.
Information based on Sizing Guidelines for Vent-Free Gas Products found on
http://www.ventfree.org.
*Square footage column based off of an 8ft ceiling height.
** Selection is based on installation locations at 2,000 ft or below. If the installation
is above 2,000 ft please contact Rinnai.
• In bathrooms, select a product equal to or less than 6,000 BTUH.
• In bedrooms, select a product equal to or less than 10,000 BTUH.
In single rooms in Region V, multiply the room’s volume by 3.20.
The result is the maximum heat input (BTUH) of the product you should consider.
NOTE: Rinnai Vent-Free Fan Convectors are intended for supplemental heating only, according
to the International Fuel Gas Code (IFGC), and should be used in applications as such. Some
states prohibit the use of unvented heaters. Check local codes for your area to verify approval
of use.