Specifications

16
After 30 minutes of maintaining
70°F, the unit will maintain 68°F
Economy Mode is designed to save gas usage over time.
The Economy Function is based on the theory that the human body cannot detect small
temperature changes over an extended period of time.
30 minutes after the set point temperature is achieved, the unit will reduce the temperature
by 2°F. After 30 additional minutes, the unit will reduce the temperature an additional 2°F.
The maximum temperature reduction will not exceed 4°F.
This reduction will not occur if the unit is undersized and cannot maintain the initial set point.
Economy Function
Initial Set point is 70°F
After 30 minutes of maintaining 68°F, the unit will
maintain 66°F. No further reduction will occur
30 60
90
0
Minutes of Operation at Set Point
Operation Temperature
66°F
68°F
70°F
72°F