Dimensions Guide

EX08CT (RHFE-202FTA2)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Safety Devices
Venting
Maximum Vent Length
Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)
Warranty
Conversion Kit
Flame rod detects flame failure; results in auto shutdown to prevent escape
of gas
Bi-metal switch, thermal fuse, and thermistor detect overheat condition;
results in auto shutdown
3 amp fuse protects against power surge; results in auto shutdown
Abnormal spark at time of ignition results in auto shutdown
Combustion fan purges any gas from the combustion chamber before
ignition
Convection fan continues to run after burner shutdown to cool internal parts
Child lock prevents inadvertent operation
Appliance shuts down if room reaches 104° F (40° C)
Concentric; 3 1/8 inch (80 mm) wall hole
No extensions allowed; flue manifold termination connects directly to unit
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
To natural gas: 204000033 To propane gas: 204000037
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Name Kit No. Fits Walls
S Vent Kit FOT-150 3 - 4 1/2 in (75 - 115 mm)
A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm)