Rinnai Corporation EX08CT, EX11CT Manual 33
If there is a power failure while the appliance is on, then the appliance will start automatically when the power is
restored.
If the appliance fails to ignite, the appliance will attempt ignition after 1 hour. The Ignition Failurefault code, 11,
will appear during that hour and disappears after a successful ignition. If ignition fails again, then the fault code
will remain and another attempt to ignite will occur in 1 hour. The fault code is not stored in the fault code history.
If the flame is extinguished during forced combustion then the appliance will attempt ignition after 1 hour. The
Ignition Failurefault code, 11, will appear during that hour and disappears after a successful ignition. Forced
combustion takes place for about 15-18 seconds before ignition. After this time, the temperature control logic
controls the combustion.
If the flame is extinguished (burner combustion failure) while the temperature control logic is operating the
appliance, then the appliance will immediately attempt ignition. No fault code will appear.
Issue
No ON
Indicator
No
Burner
Ignition
Abnormal
Combustion
Loss of
Combustion
Smell
of Gas
Noisy
Ignition
Takes to Long
to Warm Room
Remedy
Not Plugged in
Plug in
Power Failure
Restart Unit
(Initial Installation) Air
in Gas Pipe
Purge Air
(Installer)
Gas Filter Blocked
Service Call
Missed Ignition
Service Call
Flue Terminal
Obstructed
Clear Obstruction
Flue Manifold not
connected
Service Call
Louver Obstructed Clear Obstruction
Air Filter Blocked Clean Filter
Gas Escape Service Call
Child Lock Set Cancel Child Lock
Gas Off at Meter,
Tank, or Valve
Turn Gas On
ON Timer is set Cancel ONTimer
No Display
Troubleshooting
Restart Function