Specifications

8 Fan Convector Manual
Electricity
The heater requires 120 VAC, 60 Hz power from a
properly grounded circuit.
Plug the 6.5 foot (2 meter) long power cord into a
standard 3 prong 120 VAC, 60 Hz properly grounded
wall outlet.
WARNING
DO NOT use an extension cord or an adapter plug
with this appliance.
The heater must be electrically grounded in
accordance with local codes and ordinances or, in the
absence of local codes, in accordance with the
Naonal Electrical Code, ANSI/NFPA No. 70.
The heater is equipped with a three-prong
(grounding) plug for your protecon against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or
remove the grounding terminal from this plug.
Checklist for Gas and Electricity
A manual gas control valve is placed in the gas line
to the heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within limits.
Conrm that the heater is rated for the gas type
supplied.
Conrm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
An extension cord or an adapter plug has not
been used with the heater.
Final Checklist
The heater is not subject to corrosive compounds
in the air.
Clearances from the heater are met.
A manual gas control valve has been placed in the
gas line to the heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within
limits.
Conrm that the heater is rated for the gas type
supplied.
Conrm that the electricity is supplied from a 120
VAC, 60 Hz power source, is in a properly
grounded circuit, and turned on.
Explain to the customer the importance of not
blocking the warm air discharge.
Explain to the customer the operaon of the
heater, safety guidelines, maintenance, and
warranty.
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1. If installed in a manufactured home, the
installaon must conform with the Manufactured
Home Construcon and Safety Standard, Title 24
CFR, Part 3280 and/or CAN/SCA Z240 MH Series,
Mobile Homes.
The heater must not be installed in a conned
space or unusually ght construcon unless
provisions are provided for adequate
combuson and venlaon air.
The appliance is not installed in a bedroom or
bathroom.
Leave the enre manual taped to the heater or
give the enre manual directly to the consumer.
Manual gas
shut-o valve