Specifications

31
Room Temperature Thermistor
Check thermistor wiring for damage, loose or broken connections or wires.
Measure resistance of thermistor
Replace Sensor
32
Room Temperature Thermistor
Short circuit, replace thermistor
33
Overheat Thermistor
Check thermistor wiring for damage, loose or broken connections or wires
Measure resistance of thermistor
Replace Sensor
34
Overheat Thermistor
Short Circuit, replace thermistor
62
Combustion Fan Failure
Ensure fan will turn freely
Check wiring harness to motor for damaged and/or loose connections
Measure resistance of motor windings
Replace fan motor
70
ON/OFF Switch Faulty
Check wiring harness from control panel to P.C board for loose or damaged wires or
connections.
Replace control panel
71
Solenoids or Modulating Valve Circuit
Check to ensure all gas solenoids or plugged into the solenoid valves.
Check to ensure they are plugged into the correct solenoid valve.
Check resistance value of all gas solenoid valves
Replace defective solenoid.
Replace P.C. board.
72
ODS #1
ODS #2
Burner ODS #1 & Pilot ODS #2 initial
value abnormal
Verify low and high fire gas pressures were properly set.
Replace defective ODS Sensor
73
P.C Board abnormal Press the ON/Off button twice to reset heater
Fault Codes