FREESTANDING ROYALE ETR - FS35ETR FLAME FIRE Customer Operation & Installation Manual This appliance shall be installed in accordance with: • • • • • Manufacturers Installation Instructions Local Gas Fitting Regulations Municipal Building Codes Installation code AS/NZS 5601 ‘Gas Installations’ Any other local relevant Statutory Regulation Installation & Service must be performed by an authorised person. This heater is NOT designed to be inbuilt.
WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED BY AN AUTHORISED PERSON. This manual applies to the FS35 ETR Freestanding Royale - NG/LPG Table of Contents CUSTOMER INFORMATION - CONTROL PANEL .....................................................1 CUSTOMER INFORMATION - OPERATION .............................................................
CUSTOMER INFORMATION - CONTROL PANEL TIME/TEMP Display Shows either the time of day, temperatures or coded error messages. LOCK Button Indicates lock function CLOCK ADJUSTMENT AND TIMER INDICATORS Indicates that clock or dual timer programme is being set. Flame Function Med /High heat setting and overides thermostat TIMER Indicator Indicates that TIMER 1 or TIMER 2 has been selected to operate. TIME / TEMP Adjustment Increases or decreases the temperature setting as well as changing hours or minutes.
Issue 3 CUSTOMER INFORMATION - OPERATION IMPORTANT: You must read understand these instructions before operating the heater. and fully the controls. To operate the lock simply press the LOCK button. The function is activated immediately and the LOCK indicator will glow. • To Open the Control Panel Lift lightly in the centre of the lid. The control panel lid will then open backward to an angle. To Deactivate the LOCK simply press the LOCK button for 3 seconds and the LOCK indicator will go out.
CUSTOMER INFORMATION - OPERATION Remote Control The Remote Control will not turn the heater ON if Timer(s) have been selected. To manually operate when Timer(s) are not selected, simply press the ON or OFF button. To alter the temperature at anytime while the heater is operating, simply press the or button. TO REPLACE BATTERY Simply open the back of the remote control and replace Lithium battery. TYPE: CR 2032 ON BUTTON Operates the heater manually. OFF BUTTON Stops heater manually.
CUSTOMER INFORMATION - SETTING THE CLOCK Issue 3 Setting the Clock When the appliance is first plugged in or after a power failure, the digital display with show --:-- As an example, let’s set the clock to 10:35 am; Press the SET TIMES button once, the Clock indicator will flash. Press and hold the “” button; the minutes will begin to change first then the time will change by whole hours. Release the button when AM 10:00 shows on the Digital Display.
OPERATING THE TIMERS Operating the Timers Before operating the Timer(s), the clock time must be correct and a starting time and finishing time for the Timer(s) must be programmed. See page 4. The two Timers operate in the same way. This heater does not commence operation at the programmed starting time. It will attempt to heat a room by the programmed starting time. See Pre-heat, for further explanation. To select the Timer(s) to commence heating: • Check the time shown on the Digital Display is correct.
CUSTOMER INFORMATION - SAFETY POINTS Issue 3 This appliance must not be built-in. Clearances must be maintained. Do not restrict the warm air discharge by placing articles in front of the heater. Do not spray aerosols whilst the heater is operating. Most aerosols contain butane gas, which can be a fire hazard if used near the heater when it is in use.
CUSTOMER INFORMATION - SAFETY POINTS Do not allow curtains or other flammable or combustible materials to come into contact with the heater. This appliance must not be used for any purpose other than heating. Do not allow anyone to post articles through the louvres. Do not allow young children or the infirm to sleep directly in front of the heater.
CUSTOMER INFORMATION - SAFETY POINTS Issue 3 Young children should be supervised at all times. Hand or body contact with the louvres must be avoided. Do not allow anyone to sit on or lean against the appliance. Do not unplug the heater while it is in operation or while the fans are still cycling. Do not turn the heater off by unplugging it from the wall. Do not place containers of liquid on top of the heater. Liquid spillage can cause extensive damage to the appliance.
CUSTOMER INFORMATION - SAFETY POINTS Do not remove the Dress Guard. The dress guard is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently removed. For protection of children or the infirm, a secondary guard is recommended. DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS. DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
CUSTOMER INFORMATION - TROUBLE SHOOTING Issue 3 SYMPTOM POSSIBLE CAUSES SOLUTION • No power present • • • No gas present Power cut • • • Ignition failure • Smell of gas • Leaking gas • Turn off gas at meter and call installer. Fan not working • Heat Switch not activated • Allow heater to run on ‘HIGH’ for about 15 minutes. Small soot deposit • Normal operation • No action required.
CUSTOMER INFORMATION - ERROR CODES Issue 3 ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. Error Code --:-- Probable Cause Comments • Ignition Failure • Check gas is turned on.
INSTALLER INFORMATION - IMPORTANT POINTS Issue 3 Before installing this product, please read this manual carefully. Unpack the heater and check for damage. DO NOT INSTALL DAMAGED HEATER. If the heater is damaged, contact your supplier for advice. Before installing the heater, check the label for the correct gas type (see rating plate, bottom right hand side on the back of the unit). Refer to local gas authority for confirmation of the gas type if you are in doubt.
INSTALLERS INFORMATION - LOCATION Issue 3 The following pages contain information relating to Installation and Service. Installation and Service must be carried out by an authorised person only. When positioning the heater, the main points to consider are: 1. Flue connection and terminal to comply with AS/NZS 5601. Only Rinnai flueing components to be used. 2. Warm air distribution. 3.
Royale - Freestanding ETR - 14 - Issue 3 - ©Rinnai
INSTALLERS INFORMATION - SPECIFICATIONS Issue 3 Model: Freestanding Royale Flame Fire ETR FS35ETR Description: Rinnai Freestanding Radiant/Convector, glass fronted, ceramic log space heater with forced convection and natural draft flue system. Gas input rate: Natural Gas Propane Pilot and ‘Low’: 8 MJ/hr 8 MJ/hr High: 35 MJ/hr 35 MJ/hr 0.93 kPa 2.
INSTALLERS INFORMATION - DIMENSIONS Royale - Freestanding ETR - 15 - Issue 3 - ©Rinnai
Issue 3 INSTALLERS INFORMATION - FLUEING Available Flueing Options as follows: OBSTRUCTION A HEATER B HEATER C HEATER 1. Position heater taking into consideration the Information under “Location”. 2. Assemble and connect flue in accordance with the Rinnai Flueing Installation manual for Rinnai Flame Fire heaters. 3. For pipe sizing, refer to your local gas installation codes. Copper supply should be run leaving a 1/2” flared connection at the position shown. 4. Run Gas Supply. Secure the heater 1.
INSTALLERS INFORMATION - LOG INSTALLATION Issue 3 1. The log set is packed inside the heater and the packaging must be removed prior to installing the log set in its correct position • • • • • • Open both side panels. (1 screw on lower edge of each side panel). Remove fastenings on both sides of the top glass retainer. Lift retainer away from heater. Loosen screws on bottom glass retainer. Carefully lift glass out of bottom channel. Carefully remove log packaging.
Issue 3 INSTALLERS INFORMATION - TESTING & COMMISSIONING 1. To check burner pressure • Turn OFF and disconnect the 240V power supply connection. • Turn ON Gas supply. • Refer to Data Plate or the Technical Specification section in this manual for burner pressures. • If you are unable to get the unit to operate correctly, refer to Trouble Shooting on Page 9 before contacting your local service contacts listed on the back page of this booklet.
INSTALLERS INFORMATION - WIRING DIAGRAM Issue 3 WIRING DIAGRAM ETR WITH DELAY CIRCUIT AC 220V/240V XLP-02V(JST) 1 CN1 2 XLP-03V(JST) 1 2 CN3 3 (BR) (BL) YLP-03V(JST) YLR-03V 1 2 3 1 2 3 * TRANSFORMER SPARKER (GY) (GY) 4 5 6 6 5 4 3 2 1 (REAR) SV2 (BW) (RW) (R) (W) (BK) (BK) (BL) (BL) (R) CONTROL RECEIVER LO HI XLP-04V 2 4 1 3 C XMP-03V 3 2 CN8 1 917687-1 3 2 CN11 1 (BK) 917690-1 (R) 917694-1 1 FLUE BLOCK THERMISTER (W) OVER HEAT THERMISTER (BK) ROOM TEMP THERMISTER 10KR-8M (FRON
INSTALLATION / COMMISSIONING CHECKLIST Issue 3 (To be completed by certified Gas Installer) NO YES Model: _______________________________ 1. Was a Rinnai Flue system installed in accordance with the instructions? 2. Have specified gas pressures been checked and set? 3. Are decorative logs located correctly? 4. Have ember granules been placed and free of dust and powder? 5. Has the appliance been test fired for correct operation? (All Burners light without delay) 6.
CUSTOMER INFORMATION - CONTACTS The Rinnai Flame Fire Heater Family Inbuilt Royale IB35 / IB35ETR Australia Pty. Ltd. Head Office Freestanding Royale FS35 / FS35ETR Inbuilt Slimfire IB25 ABN 74 005 138 769 Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au 10-11 Walker Street, Braeside, Victoria 3195 P.O.