HOME OWNER / INSTALLER FOR YOUR SAFETY THIS MANUAL MUST BE READ IN ITS ENTIRETY BEFORE OPERATING HEATER FS35ETRBN/US FS35ETRSN/US FS35ETRBL/US FS35ETRSL/US Gas Radiant Space Heater Owners Operation and Installation Manual WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
LIMITED WARRANTY RINNAI FIREPLACE HEATER WHAT IS COVERED? This Warranty covers any defects in materials or workmanship, subject to the terms stated below. This Warranty extends to the original purchaser and subsequent transferees, but only while the product remains at the site of the original installation. This Warranty only extends through the first installation of the product and terminates if the product is moved or reinstalled at a new location.
WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. This manual applies to the following models only: FS35ETRBN/US FS35ETRSN/US FS35ETRBL/US FS35ETRSL/US Freestanding Fire ETR Electronic Timer Remote Table of Contents Limited warranty ....................................................................................
SPECIFICATIONS Model: Description: Output: Gas Control: Burners: Warm Air Discharge: Flue: Ignition: Power Supply: Rating Plate Location: Weight: FS35ETRBN/US, FS35ETRSN/US (NG) United States FS35ETRBL/US, FS35ETRSL/US (Propane) United States Freestanding radiant/convector, glass-fronted, ceramic log space heater with forced convection and natural draft flue system 24,000 Btu/hr Natural Gas 22,000 Btu/hr Propane Electronic control valve Ember bed, flame and heat burner Top front louvres Natural draft.
IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS Unpack the heater and check for damage (DO NOT INSTALL DAMAGED HEATER). If the heater is damaged, contact your supplier for advice. Before installing the heater, check the label for the correct gas type (see rating plate, bottom right hand side of pillar). Refer to local gas authority for confirmation of the gas type if you are in doubt.
of the control system and any gas control which has been under water. 24 The draft hood on the appliance should be installed in the same atmospheric pressure zone as the combustion air inlet to the appliance and shall be located so that the relief opening is accessible for checking vent operation. 17 Adequate clearances for accessibility for purposes of servicing and proper operation should be provided. 18 Adequate clearances around air openings into the combustion chamber should be provided.
38 WARNING: DO NOT OPERATE APPLIANCE WITH THE FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE ARE KEPT CLEAN. 35 The glass window shall be replaced as one piece as supplied by the manufacturer. See log and glass installation on page 15. 39 WARNING: Electrical grounding instructions.
FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A This appliance is equipped with an ignition device which automatically ignites the pilot. Do not try to light the pilot by hand a neighbor’s phone. Follow the gas suppliers instructions. • If you cannot reach your gas supplier call the fire dept. B. BEFORE OPERATING smell all around the appliance area for gas.
CONTROL PANEL LAYOUT For your convenience the controls on your new Flame Fire are situated under the cover on the top right-hand side of the fire and are accessed by simply lifting the lid. All necessary adjustments to the operation of your fire can be made with these controls. OPERATION • TURNING ON fan is running. Press the ON/OFF button to operate the unit. The ON indicator will glow green.
deactivate the LOCK press and hold the button for 3 seconds until the indicator goes off. you have selected AM or PM as required, a small indicator on the left hand side of the Digital Display indicates the AM/PM setting. During normal operation the LOCK may be activated and all controls, other than the OFF switch, will be locked. Deactivating the LOCK releases the controls. Use the buttons again to set the minutes. Scroll up or down using the buttons until the correct time is reached.
again when the power comes back on, but the time will be slow by the duration of the power failure. To set the clock to the correct time after the power has come back on, simply follow the instructions on page 10. proceed to TIMER 2 - which is programmed in the same way - or three times to return to the clock display. This must be done within 1 minute of setting the time to lock it into the memory. The digital display will show the current time.
• TO REPLACE REMOTE CONTROL BATTERY ON BUTTON Operates the unit manually. The battery is held in a clip that slides out the bottom of the remote control. The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards. OFF BUTTON Stops unit manually. The battery must be of type CR 2032 and will only operate if installed the right way up, as shown below. TEMPERATURE ADJUSTMENT Increases or decreases the temperature setting.
LOCATION When positioning the heater, the main points governing the location are: 5. The heater is not designed to be built into bookcases or shelves or any combustible opening. 1. Flue connection and proper venting 2. Warm air distribution. 3. Adequate air supply. 6. Check that room ventilation complies with local regulations. 4. The heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases, curtains may need restraining. 7.
VENTING Use only an approved B vent system • Suspend a plumbline from the ceiling to the centre of the flue socket. horizontal at any stage. There must not be more than 2 bends in any system. Any horizontal section of flue must be less than 1/3 the length of vertical flue which follows it. • Mark the centre of the flue in the ceiling. See below diagram • Make a small hole in the ceiling and double check that the flue system will be at least 1” clear of combustible materials.
LOG INSTALLATION The logset is packed inside the unit and the packaging must be removed prior to installing the logset in its correct position. • Open both side panels. • Remove fasteners on both sides of the top glass retainer. • Lift retainer away from unit. • Loosen screws on bottom glass retainer. • Carefully lift glass out of bottom channel. • Carefully remove log packaging. The logset has two holes underneath for location onto the pins inside the unit.
TESTING AND COMMISSIONING • TESTING PROCEDURE • TO CHECK BURNER PRESSURE It is the responsibility of the installer to check that under normal operating conditions of the appliance, all flue gases are exhausted to the outside atmosphere and that there is no spillage of combustion gases into the room. • Refer to rating plate. COMMISSIONING • Remove the wiring cover panel. • INSTALLATION / COMMISSIONING CHECKLIST Turn gas supply on and plug the unit into the power supply.
MAINTENANCE INSTRUCTIONS IMPORTANT MAINTENANCE INSTRUCTIONS ANNUAL INSPECTION A heater should not be used if you suspect there may be a problem, and a service agent must be called to investigate the cause of the problem. The unit should be inspected at least once a year by a qualified service technician including inspection of the flue system. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. Normal • CLEANING INSTRUCTIONS.
The heater should be serviced annually only by an authorised person. • GLASS REPLACEMENT AND CLEANING. (May be performed by the owner) 4 2 2 3 It is best to handle the glass with clean gloves to avoid smearing the glass with finger prints which might show after replacement. 1 1 Refer diagram opposite Loosen the side panel retaining screws.(1) Access can now be obtained to the two top glass retaining screws.
WIRING DIAGRAM Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WIRING DIAGRAM-LADDER TROUBLE SHOOTING SYMPTOM Burner will not light Smell of gas Fan not working Fan does not stop Small soot deposit CAUSE No power present No gas present power cut Air in gas pipe Ignition failure Leaking gas Heater still warming up Heater cooling down Normal operation Inadequate flue system Soot deposit forming on Log misalignment glass or logs Incorrect gas pressure Condensation on glass Normal operation Streaky lines on glass Normal operation Digital error message on Electronic fa
ERROR CODES • ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. Error code Probable cause Comments Check gas is turned on. Service call if repeated Check gas is turned on.
EXPLODED DIAGRAMS 22
SPARE PARTS LIST ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 23 24 25 26 27 28 29 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 QTY. 1 1 1 6 2 1 1 1 1 1 1 1 1 1 9 9 1 1 9 3 1 1 1 1 1 1 1 1 6 2 2 4 2 2 2 2 2 2 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 PART NO.
51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 1 1 1 1 1 2 1 1 2 2 2 4 2 2 1 1 1 1 1 5 5 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7988V 7988SP 7472 7062 7060 7564 7482V 7482SP 7136 9200 9025 7050 7240 9115 7019V 7019SP 7018V 7018SP 7063 7029 7029BN 7099 7099BN 4996 7004 7033 7037 7518 5327G 7513 4991 4992 6308 6313 7536 7537 7539 7542 7544 7507 7549 7491 7545 7545S 7512 7541 7514 7540 7899 REAR PANEL FS35ETR VIPER
INSTALLATION NOTES 26
INSTALLATION / COMMISSIONING CHECKLIST NO YES 1. Was a fireplace inspection carried out? (i.e. clearances, combustibles etc.) 2. Was a manufactured flue system installed? 3. Has specified gas pressure been set? 4. Are decorative logs located correctly on pins? 5. Have ember granules been placed and free of dust and powder? 6.Has the appliance been test fired for correct operation (All burners light without delay) 7.