Securely screw the top and boom
brackets into the wall, making sure
the screws are ush with the wall.
Use any of the holes in the top
and boom brackets.
Make sure the securing method is
sucient to support the weight of
the boiler. Refer to the boiler
weight in secon “3.4
Specicaons” of this manual.
Top
Bracket
Boom
Bracket
The boiler must be installed in an
upright and level posion. Do not
install the boiler upside down or on
its side.
IMPORTANT
The condensate collector must be lled with
water prior to installing the vent system.
Pour approximately 10 ounces (1.25 cups) of
water directly into the boiler’s exhaust port
(do not remove the 2 in. PVC adapter prior to
this).
Before operaon of the boiler, the
condensate collector must be lled with
water. This is to prevent the potenal of
exhaust gasses from entering the building.
Failure to ll the condensate collector could
result in severe personal injury or death.
Exhaust
Port
WARNING