Installation Manual

Rinnai I-Series Condensing Boiler Solo Manual 65
Parameter
Number
Seng Descripon
Selecon
A b C d
Indirect Tank Supply
Temperature with Thermistor
Control
180°F
(82°C)
Seng
Temperature
+18°F
(+10°C)
Seng
Temperature
+27°F
(+15°C)
30
Indirect Tank Supply
Temperature with Thermostat
Control
180°F
(82°C)
160°F
(71°C)
140°F
(60°C)
31
Allowed Indirect Tank
Temperature Drop before
Firing (with Thermistor)
5.4°F
(3°C)
10.8°F
(6°C)
16.2°F
(9°C)
21.6°F
(12°C)
32
Indirect Tank Operaon Opon Use Pump Use 3-Way
Valve
33
Indirect Tank Simultaneous
Heang
Indirect Tank
Priority
Simultaneous
Heang with
Indirect Tank
and CH
34
Indirect Tank Priority Time 60
minutes
40
minutes
90
minutes
35
CH Temperature Limitaon to
Allow Simultaneous Operaon
with Indirect Tank
Yes No
NOTE
Refer to secon “12.4.1 Parameter Sengs Tablefor more informaon on parameter sengs.