Specification

CONDENSING WALL-MOUNTED, GAS-FIRED COMBI BOILER
(CENTRAL HEATING AND DOMESTIC HOT WATER)
Models i060C, i090C, i120C
Appliance
Wall-Mounted, Gas-Fired Combi Boiler
Installaon
Indoor
Gas Type Natural Gas (or Propane with included eld conversion kit)
Standard
Features
Factory Installed Pump
Outdoor Reset Control System with Sensor
Simultaneous DHW and Heang Capability
Built-in DHW Plate Heat Exchanger
Modulang Stainless Steel Mesh Burner
Stainless Steel Water Tube Heat Exchanger
Direct Vent Sealed Combuson
Approved for Room Air and Closet Installaons
Included
with Boiler
Purchase
Propane Field Conversion Kit
Wall Mounng Bracket
CH Pressure Relief Valve (30 PSI)
Outdoor Temperature Sensor
Integrated Vent Adapter for 2 in. PVC, PP and
3 in. x 5 in. Concentric Venng
Documentaon: Installaon and Operaon Manual,
User Manual, and Technical Data Sheet
Accessories
Primary-Secondary Heang Kit (PN: 807000212),
Condensate Neutralizer (PN: 804000074), ScaleCuer (PN:
103000038), DHW Isolaon Valve Kit (PN: MIVK-T-LW),
and Temperature Controller (PN: MC-601)
Venng
Opons
Direct Vent (Concentric and Twin Pipe)
Room Air
Ubbink Flex Vent
Materials: Polypropylene, Stainless Steel, PVC, CPVC
Refer to the Rinnai I-Series Boiler Installaon and
Operaon Manualfor approved venng.
Measurements: in. (mm)
Maximum Equivalent Vent Lengths
45° elbow equivalent to 3  (1 m). 90° elbow equivalent to 6  (2 m).
Concentric, Twin Pipe, and Room Air:
Vent Sizes
2 in. PVC
2 in. (60 mm) PP
2 in. x 4 in. Concentric
3 in. PVC
3 in. (80 mm) PP
3 in. x 5 in. Concentric
Maximum
Vent Lengths
65  (20 m) 150  (46 m)
Ubbink Flex:
Vent Sizes 2 in. PP
Maximum Vent Lengths 50  (15 m)