Installation Guide

108 Rinnai I-Series Condensing Boiler Solo Manual
4. Place the boiler in operaon by a call for heat.
5. The boiler iniates one start-up aempt and mulple restart aempts.
Aer the last start-up aempt, the boiler locks out and the gas valve shuts o. Code 110
appears on the controller display which indicates ignion system safety shuto.
6. Reconnect the wiring connecon to the ame rod. Be careful not to touch the inside of the
wiring connecon. To reset the error, press the Central Heang buon. The boiler starts up.
1. Ensure the boiler is not currently ring and the ame rod is not hot.
2. Remove the boiler front panel.
3. Disconnect the wiring connecon from the ame rod (located on front of the boiler under the burner).
7. Replace the boiler front panel.
8. The boiler may now go back into normal operaon.
Do not touch the inside of the wiring connecon while it is disconnected.
Boiler front side
Burner
Flame Rod
Remove wiring
connecon
WARNING