Full Product Manual
16 Rinnai I-Series Condensing Combi Boiler User’s Informaon Manual
The available DHW set point
temperatures are provided below. When
the unit of measurement changes (°C/°F),
the corresponding temperature in the
table changes.
Factory Default: 104°F
The factory default maximum
temperature is limited to 120°F. To select
temperatures above 120°F (49°C), the
DHW Maximum Setpoint Temperature
will need to be adjusted. Please refer to
the “Rinnai I-Series Condensing Boiler
Installaon and Operaon Manual” for
further details.
Water temperatures over 125°F (52° C)
can cause severe burns or scalding
resulng in death.
Hot water can cause rst degree burns
with exposure for as lile as:
3 seconds at 140°F (60°C)
20 seconds at 130°F (54°C)
8 minutes at 120°F (49°C)
Children, disabled, or elderly are at
highest risk of being scalded.
Feel water before bathing or
showering.
DANGER
This boiler requires a minimum ow rate of
0.4 GPM to operate. In some cases when
you are not geng hot water or if the water
alternates between hot and cold, it is due to
the water ow being below or close to the
minimum ow rate. Increasing the ow rate
should resolve these problems.
Fahrenheit (°F)
98
100
102
104
106
108
110
112
114
116
118
120
125
130
135
140
If you are experiencing uctuang water
temperatures at a xture, this may be due
to a high temperature seng on your boiler
(130°F-140°F). Decreasing the setpoint
temperature may alleviate the uctuaons
and deliver a stable temperature.
Celsius (°C)
37
38
39
40
41
42
43
44
45
46
47
48
49
50
52
54
56
58
60
Temperature Sengs