Full Product Manual
Rinnai I-Series Condensing Combi Boiler User’s Informaon Manual 23
4
Consumers should never aempt any acon that they are not qualied to perform.
DHW
Hot water is not
available.
Check that the gas is turned on at the boiler, gas meter, or cylinder.
When using propane gas, is there sucient gas available?
Is the water supply valve o or disconnected?
Is the faucet opened suciently?
Is the DHW inlet lter clean?
Is the boiler or other system piping frozen?
Is the DHW switch On?
If the water ow volume is very small, the boiler will not acvate.
Turn on the faucet fully to allow for a greater ow demand.
The DHW
temperature and
pressure are
uctuang.
Is there sucient water pressure?
Is the setpoint temperature of DHW adequate?
When the boiler is running in DHW and CH operaon, the DHW
temperature may uctuate.
When there is a long, uninsulated piping length between the boiler and
xture, the hot water temperature uctuates. Ask the dealer to add
insulaon on the piping or increase the setpoint temperature.
The boiler ceases
to re during a
DHW demand.
Check that the gas is turned on at the boiler, gas meter, or cylinder.
When using propane gas, is there sucient gas available?
If the water ow volume is very small, the boiler will not acvate. Open
a faucet more to allow for a greater ow demand.
Reset the boiler by closing and opening the faucet again.
The amount of
hot water is
uctuang.
When DHW is used in mulple faucets at same me, the amount of hot
water may be restricted.
DHW may be restricted. The water supply pressure or system piping may
aect the hot water volume.
Aer the power is
out or the power
plug is pulled out,
the setpoint
temperature has
changed.
The setpoint temperature may change aer the boiler has had power
restored. The setpoint temperature must be entered again.
If you believe the boiler is not operang as designed, check possible reasons from the list below.
If an Error Diagnosc Code appears, contact a local Service Provider.