Full Product Manual
24 Rinnai I-Series Condensing Combi Boiler User’s Informaon Manual
Central
Heang
The room
temperature is not
geng warm.
Is the target setpoint temperature of central heang appropriate
for your applicaon? (Refer to the “Target Setpoint
Temperatures” table in secon 3.6 of this manual.)
When an outdoor sensor control is used, the supply temperature
for central heang will vary depending on the outdoor
temperature. To change the seng, contact your dealer.
When using DHW with priority seng ON, central heang may be
in standby. To change the seng of the simultaneous heang
and DHW operaon, contact your dealer.
Check that the gas is turned on at the boiler, gas meter, or
cylinder.
When using propane gas, is there sucient gas available?
Controller
The CH buon does
not work.
If the boiler is set up for CH via a room thermostat, the CH buon
will not work to operate the boiler.
The seng
temperature of
DHW cannot be set
higher than 120°F
(49°C).
The maximum temperature seng may be selected at 120°F
(49°C). To change the seng, contact your dealer.
Cannot change the
DHW set point
temperature
While DHW is being provided, the temperature can only be
adjusted between 98°F and 110°F.
Others
The sound of a
pump occurs when
neither CH or DHW
are in use.
When the outdoor temperature is low, the freeze prevenon
operaon may start with pump operaon.
When the boiler is not acvated, the pump may operate for
prevenng locking up. The pump is operang to enable quicker
output of DHW from the boiler.
The boiler does not
begin operaon
aer power has
been restored.
When power has been restored aer a power outage or the
power plug is disengaged, the boiler will not start operang while
inializing. Wait for 5 minutes and start using the boiler as
normal.
Cannot turn o Eco
Mode switch.
During DHW recirculaon, Eco will always be on.