Full Product Manual

Rinnai I-Series Condensing Combi Boiler Users Informaon Manual 27
Maintenance is required to maintain safe operaon of the boiler.
The boiler must be inspected annually by a licensed professional. Repairs and maintenance
shall be performed by a licensed professional. The licensed professional must verify proper
operaon aer servicing.
Keep the boiler area clear and free from combusble materials, gasoline, and other
ammable vapors and liquids.
To protect yourself from harm, before performing maintenance:
Turn o the electrical power supply by unplugging the power cord or by turning o the
electricity at the circuit breaker. (The boiler controller does not control the electrical
power.)
Turn o the gas at the manual gas control valve, usually located immediately below the
boiler.
Turn o the incoming water supply. This can be done at the isolaon valve immediately
below the boiler or by turning o the water supply to the building.
If you encounter a problem that is dicult to solve, stop the operaon and immediately
contact a licensed professional.
5
5
MONTHLY
Boiler Area
Verify the area is free of combusble materials, gasoline and other ammable vapors and liquids.
Verify the area is clean from dust and obstrucons.
Verify the air intake area is free of any contaminants listed in the Rinnai I-Series Condensing
Boiler Installaon and Operaon Manual.Any contaminants in the boiler intake air vicinity must
be removed. If they cannot be removed, contact a licensed professional.
Piping
Inspect all water, gas, and condensaon piping for leaks. Look for signs of leaking lines or
corrosion.
Conrm the condensaon line is not blocked. If a condensaon drain pump is used, conrm the
condensaon drain pump operates correctly.
Venng
Verify the boiler vent discharge and air intake is clean and free of obstrucons.
Check for leakage, damage, or deformaon of venng.
Boiler
Verify the boiler is free from any abnormal situaons, such as diagnosc error codes, loud noises,
leakage or other potenal issues.
Check that the pressure on the controller display or external pressure gauge indicates 17 to 26 PSI
(117 to 180 kPa).