Gas input rate:
Natural Gas Propane
Pilot / front:
7.7 MJ/hr 9 MJ/hr
Medium:
14.2 MJ/hr 15.8 MJ/hr
High:
25 MJ/hr 25 MJ/hr
Low:
8 MJ/hr 9 MJ/hr
Burner Pressure: High:
0.92 kPa 2.0 kPa
Gas Connection: 1/2” BSPF male flare to barrel union
Flue terminal: 43 x 245 rear discharge
Fan: Tangential 2 speed, power rating 28 Watts
Combustion system Multi port burner
Logs: Ceramic
Ignition system: Continuous spark electronic ignition
Operation: Push button to light pilot and burners
Safety Devices: Flame failure thermocouple
Overheat Bi-metal strip / Fan delay Bi-metal strip
Combustion method: Naturally aspirated burner
Installation type: Inbuilt only
Flue requirement: Can be flued directly into a sealed chimney as per
AS 5601 or fitted with a Rinnai approved flue system
750
645
35
25
277
310
582
528
TECHNICAL SPECIFICATION
INSTALLERS INFORMATION - DIMENSIONS