Data Sheet

Rinnai Continuous Flow and Instantaneous Hot Water Warranty 7
TABLE 2WATER CHARACTERISTICS
Rinnai
water heater
system type
Total
Dissolved
Solids
(TDS)
mg/Litre
or ppm
Hardness
(as
CaCO3)
mg/Litre
or ppm
Saturation
Index
(Langelier)
pH
Dissolved
CO2
mg/Litre
or ppm
Chlorides
mg/Litre
or ppm
Continuous ow
& Instantaneous
water heaters
Not
Applicable
200
+0.4 to -1.0
@ 65
O
C
5.5 to
9.5
18
Not
Applicable
10. This warranty applies to water heaters connected to a water supply where the water
chemistry and impurity levels do not exceed the limits specied in Table 2.
11. For solar hot water applications, the models in Table 1 must be converted by Rinnai to
be solar compatible and must be installed as a component of a Rinnai solar hot water
system. If the appliance is converted for solar hot water applications after it is rst
installed, the balance of the original warranty in Table 1 will remain eective.