User Manual

Flued Heating Specications
Specs
Visual
Dimensions
(mm)
H 695 554 582 750 670 670 653 653 650 650 650 650
W 465 750 760 550 930 930 910 910 910 910 910 910
D 257 250 257 250 330 330 164 404 125 302 125 302
Inbuilt Cavity
Dimensions
(mm)
H - - - - - - 605-635 - 605-635 - 605-635 -
W - - - - - - 710-805 - 710-805 - 540-805 -
D - - - - - - Min.330 - Min.270 - Min.270 -
Colours White White White
White
or Silver
White Beige or Gunmetal Beige or Brown
Gas Type
NG/
LPG
NG
Only
(1)
NG/
LPG
NG/
LPG
NG/ LPG
NG
Only
(1)
NG/LG NG
(1)
Only
Gas Input
MJ/h
Low 6 9 9 9 11 11 15 15 7
High 13 23 23 23 37 37 30 30 28
kW Output 2.9 5.4 5.2 5.4 8.6 8.6 7.0 5.2 5.2
‘Heats
up to Capacity
(m
2
)
Very Cold 27 47 47 47 75 75 59 45 41
Cold 32 56 56 56 89 89 70 53 49
Cool 42 74 74 74 119 119 95 70 65
Mild 49 85 85 85 138 138 109 81 75
AS4553 Eciency
Star Rating
4.6 4.3 4.3 4.2 4.3 4.3 4.4 1.0 2.1
AS4553 Emissions
Star Rating NG & LPG
6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0
Thermostatic or
Manual Control
Thermostatic Manual 3 Settings
Dual Timers Yes Yes Yes Yes
Delay Timer (FDT) Yes Yes Yes Yes
Dual Weekday & Weekend
Timers
Yes Yes
Preheat feature Yes Yes Yes Yes Yes Yes
Economy Mode Yes Yes Yes Yes Yes Yes
Auto O Mode Yes Yes Yes Yes Yes Yes Yes Yes
Override Button Yes Yes Yes Yes Yes Yes
Child Lock or
Lock Button
Yes Key Yes Yes Yes Key Yes Yes
Warranty
Domestic
Heat
Exchanger
10 years Pro Rata
(3)
10 years Pro Rata
(3)
Fan 2 years 2 years
All Other
Parts
1 year 1 year
Free Labour 1 year 1 year
(1) LPG conversions are available at an additional cost and are made to order.
(2) FDT models catered to commercial applications.
(3) Full replacement costs in the rst year, reducing 10% per year thereafter. Dimensions are subject to production tolerances and may vary slightly from those
given.
Rinnai Australia Pty. Ltd. Reserves the right to make modications and change specications without notice. We will however endeavour to communicate any
major changes well before implementation.
240V power is required with all models and a power cord & plug is tted. In most cases this cord is on the right hand side. To hide the power cord, it is permissible
to have the unit ‘hardwired’ behind wall cavities as long as it is in accordance with the Standard AS/NZS3000 and done by a qualied electrical tradesperson such
as an electrician. In short, this means that it must be wired with an accessible double pole isolation switch.
14
Specications
309FT 556FDT
(2)
559FT 557FTR 1004FTR 1004FDT
(2)
Energysaver®
Ultima II 2001 Spectrum