CONNECTING HEATER EXHAUST & AIR SUPPLY
CONNECTING HEATER EXHAUST
This section describes how to connect the exhaust pipe from the Energysaver heater to the exhaust connection
onflue transitions of ESDFK and ESKIT03.
1. Lubricate the O-Ring of the exhaust connection and fit to the exhaust pipe of the heater.
Push the exhaust pipe fully home so that the end of the exhaust connection and the collar of the exhaust
pipe are fully mated.
2. Attach the flue locking clamp provided with the heater over the exhaust pipe and transition adaptor.
Ensure that the teeth of the flue locking clamp engage both
A the collar of the exhaust pipe and B the
channel in the transition adaptor.
3. Close the clamp until the tab locks to secure both components together.
This joint MUST BE properly secured in accordance with these instructions using the clips
provided.
If this joint is not secured properly, products of combustion could disperse into the room being
heated which may result in a dangerous condition.
For 1004 and 1005 models an additional flue component “Flue Adaptor” is supplied with the heater
which steps down the larger diameter heater exhaust to that used by the exhaust connection on
the flue system.
Exhaust Connection
ESDFK ESDFK
(When modified for use with “Sideways”
and “Under Floor” installations)
ESKIT03
CAUTION
1
2
!
!
A
!
B
Exhaust pipe (Telescopic on models 556,557,
559, 561, 1004 & 1005) .
(Fixed length on models 308 & 309)
Exhaust connection
!
IMPORTANT
!
!