Installation Guide
Rinnai Australia 7 ES Flue Installation Manual
WALL PENETRATIONS
Below are diagrams and associated dimension tables for wall penetrations for each Energysaver heater model.
Table 1.
RHFE 308 RHFE 309
RHFE 556 RHFE 559
RHFE 557/561 RHFE 1004/1005
All dimension are in millimetres
RHFE 308 RHFE 309 RHFE 556 RHFE 557 RHFE 561 RHFE 559 RHFE 1004 RHFE 1005
i Width of appliance 426 465 750 550 545 760 930 930
ii Centre-Line of appliance 213 233 375 275 273 380 465 465
iii Arc axis (Axis point of the flue elbow) ————————
A Horizontal distance from Centre-Line to
arc centre
110 132 220 172 172 207 305 356
B Vertical distance from base to arc centre 265 265 215 264 267 247 165 129
C Minimum horizontal limit of arc 150 150 240 200 200 240 325 376
D Minimum vertical limit of arc 265 120 215 264 267 120 250 250
E Maximum vertical limit of arc 415 410 310 390 393 440 340 340
F Maximum horizontal limit of arc 150 150 300 230 230 305 365 416
G Penetration diameter 100 100 100 100 100 100 100 100
D
B
E
A
i
ii
G
C & F
iii
i
C & F
iii
ii
B
D
E
A
G
D
B
E
A
C
F
G
ii
I
iii
A
iI
ii
C
F
D
E
B
iii
D
B
E
A
C
F
G
ii
i
iii
D
B
E
A
F
C
G
ii
i
iii