Installation manual

Rinnai New Zealand Limited Neo Installation Manual: 11906-B
02-11
22
Test pressures
To check and set the burner pressures
1. Refer to the data plate located inside the appliance on the front left hand side for the
correct gas pressure settings.
2. Using a screw driver loosen the captive Appliance Test Point Pressure Screw (ATPP) and t
the manometer.
3. Remove the dust cap from the regulator adjusting nut and screw.
Gas control valve
High pressure
adjusng nut
Low pressure
adjusng screw
Gas
inlet
Inlet test
point
Cap
Gas outlet
Appliance test point
pressure
Gas control power connecon