Checking the ame paern
It may take approximately two hours of operation for the logs to achieve their full ame
pattern and glow. During the initial burning in period, some smoke and smell may be
experienced. The appliance should be run on the high setting in a well ventilated room until
these dissipate. It is important to check the ame pattern during this time.
Abnormal ame paern
Abnormal ame performance and/or pattern can indicate a problem with the re, such as
blocked gas injectors, log movement during installation or incorrect ue installation. There are
some warning signs that could indicate a problem.
• Unusual smell from the appliance
• Continued diculty or delay in establishing a ame
• Flame appears either very short or very long
• Flame only burns part way across the burner
• Severe soot building up on the inside of the glass door
Normal flame paern
Abnormal flame paern
Soot build up
It is the responsibility of the installer to check that under normal conditions of the
appliance, all ue gases are exhausted to the outside atmosphere and that there are no
spillage of combustion gases into the room.
If the appliance cannot be made to perform correctly, please contact Rinnai.