Specicaon
Description Inbuilt gas space heater
Burning log eect
Glass front with glass dress guard
Convection fan, top air discharge
Installation Inbuilt masonry, inbuilt mock chimney, and freestanding options
Combustion Method Bunsen type burner
Data Plate Inside appliance on the front left hand side
Flue - Masonry Rinnai strongly recommends the use of a Rinnai exiliner ue system (exi Ø 100 mm).
Failure to meet this criteria may result in an unsafe situation.
Installation without a exiliner ue is permissible as long as the chimney is checked for
soundness and ability to achieve a good draw. Terminal 240 mm x 45 mm rear discharge
(spigot).
Flue - Decorative
(mock chimney) and
Freestanding
Natural draft twin skin ue. An approved 100 mm cowl must be tted to all installations.
Decorative chimney installations require a Rinnai zero clearance box and zero clearance
ue kit.
Flue dimensions:
Outer - 150 mm
Inner - 100 mm
Gas Connection
½ " BSPT, the gas supply terminates inside the heater at the front lower right hand side
of the appliance
Gas Type NG and General Product LPG
Convection Fan 2-speed centrifugal, double diameter 160 x 180 mm
Heating Area Up to 107 m
2
(NG)
Up to 93 m
2
(ULPG)
Ignition Continuous spark electronic ignition
Input/Output
Input NG: 14-30 MJ/h
Input ULPG: 14-27 MJ/h
Output NG: 3.24-6.94 kW
Output ULPG: 2.98-6.04 kW
Noise Level 37-45 dB(A)
Power Consumption High 50 W
Standby <3 W
1500 mm cord is supplied with 3-pin plug on the rear left of the appliance
Safety Devices Overheat switch, electrical fuse, ame failure sensing system, and power failure
protection
Temperature Control
Manual models, manual control on unit
ETR models, thermostatic, temperature control range 7-32 °C
Thermal Eciency NG - 80.5%
ULPG - 80%
Eciency star rating: 4.10 stars
Weight 60 kg