User manual

Installation & Servicing Instructions Rinnai Q-Series
58
11.2Activatingfactorysettings(greenbuttonfunction)
To activate the factory settings again please follow the next procedure (Note: all altered
adjustments will be set back to the original factory settings that are accessible in the
current service level the boiler is in either user or 123):
- Select, when necessary, the technical read out;
- Select with the MODE-button chapter PARA;
- Press the STORE-button.
The word "Copy" will appear and factory settings are active again.
12 Isolatingtheboiler
Some situations require turning the entire boiler off.
By switching off the three buttons with the LED's for central heating, hot water and
pump program (
, or ), the boiler is switched off. Do not shut off the power
of the boiler, which means the circulation pump and the three-way valve are activated
once every 24 hours in order to prevent these parts from seizing up.
Intheeventoffrostdangerduringanisolatedboileritisadvisabletodrainthe
boilerand/ortheinstallation.
!
CAUTION