Installation manual

Rinnai Australia 22 Ultima II Installation Manual
CONSOLE INSTALLATION, CAVITY TWIN SKIN FLUE
12. INSTALL HEATER
Mark position of top of spacer on wall.
Fit wall clips.
Feed the copper tube through the supply access
opening.
Install heater, ensure spigot is correctly engaged
into elbow.
Replace top spacer, clipping the spacer into the
wall brackets at the same time as attaching it to the
heater.
Secure top spacer with the four screws provided.
The heater is now secured to the wall.
13. INSTALL RADIANTS
Remove glass panel, install radiants as shown.
Replace glass panel.
14. CHECK FOR GAS ESCAPES
Use a manometer or soapy water.
DO NOT USE A NAKED FLAME.
15. CLOSE GAS SUPPLY COVER
This seals the heater from the chimney and prevents
chimney draughts affecting the performance of the
heater, as well as preventing the entry of debris from
the chimney.
16. TEST APPLIANCE
See page 26.
17. INSTRUCT CUSTOMER
Instruct customer on operation and servicing of the
appliance.
Remind customer of dress guard requirements.