Installation manual

Rinnai Australia 25 Ultima II Installation Manual
CONSOLE INSTALLATION, MASONRY FIRE PLACE
8. INSTALL HEATER
Fit right and left rear covers to heater.
Place top spacer (covers) in position temporarily for
wall marking.
Attach flue spigot extension to heater.
Feed the copper tube through the supply access
opening.
Secure heater to the fireproof material using the
clips in the top spacer (covers).
Connect and tighten the gas supply.
9. INSTALL RADIANTS
Remove glass panel, install radiants as shown.
Replace glass panel.
10. CHECK FOR GAS ESCAPES
Use a manometer or soapy water.
DO NOT USE A NAKED FLAME.
11. CLOSE GAS SUPPLY COVER
This seals the heater from the chimney and prevents
chimney draughts affecting the performance of the
heater, as well as preventing the entry of debris from
the chimney.
12. TEST APPLIANCE
See page 26.
13. INSTRUCT CUSTOMER
Instruct customer on operation and servicing of the
appliance.
Remind customer of dress guard requirements.