Installation manual
Rinnai Australia 28 Ultima II Installation Manual
SPECIFICATIONS
PRODUCT SPECIFICATIONS
Model: REH-311FTB INBUILT / REH-311FTC CONSOLE
Name: Ultima II INBUILT / CONSOLE
Rinnai reserves the right to change or modify specifications without notice.
DIMENSIONS
*The total installation depth includes the dress guard and where applicable the rear cover kit.
General description: Rinnai Ultima II
Radiant / Convector, Forced Exhaust, Fully Automatic Space Heater.
Gas input rate: Natural Gas Propane
High (MJ/hr): 30 30
Low (MJ/hr): 15 15
Gas control: Rinnai Electronic control with Rinnai Solenoid Valves
Burners Stainless Steel Ribbon Type
Gas Inlet: Barrel Union / Flare Fitting (15 mm flare connection)
Test Point Pressure: High (kPa) 0.98 2.15
Low (kPa) 0.26 0.56
Flue System: Forced exhaust, for twin skin flue or fireplace installation
Fan: Tangential 3 speed 32 Watt rating
Flue Termination: An approved 100 mm cowl must be fitted to all installations.
Combustion Fan: 2 - pole shaded pole induction motor (with revolution detection)
Sirocco fan (240 V)
Ignition system: Electronic automatic ignition
Power Supply: 240 V / 50 Hz. Heater is fitted with a supply lead and 3 pin plug.
Replace only with Rinnai Part Number 90192303.
Data Plate: Bottom left hand side, behind front panel.
Installation type: Console or Inbuilt
Weight: Console: 41 Kg. / Inbuilt: 38 Kg.
Legend
CONSOLE
A 910 mm C 265 mm E 13.6 mm G 600 mm I 114 mm
K
Total Installed Depth*
B 653 mm D 24 mm F 93 mm H 280 mm J 393 mm 404 mm
INBUILT
A 910 mm C 140 mm E 138.6 mm G 600 mm I 114 mm
K
Total Installed Depth*
B 653 mm D 24 mm F 93 mm H 280 mm J 393 mm 164 mm
AC
D
K
E
JG
H
F
B
CONSOLE
I
F
I
GJ
H
K
C
D
E
INBUILT