Installation manual

Rinnai 11 RF1800 OIM
CLEARANCES, MANTELS, SURROUNDS, RECESSES & HEARTHS
Clearances
The appliance must be installed with the shown
minimum clearances to combustible materials.
Mantles
A timber mantel may be installed above this appliance
but must be within the grey area as shown here.
Timber Surrounds
As with mantels when a timber surround is to be tted,
ensure it complies with minimum timber clearances
of 300mm above and 150mm to each side.
Recesses
If the appliance is to be installed into a recess the
recess must comply with the limitations shown right.
NOTE
The same limitations apply to the sides
of the appliance.
TV or Ornamentation Above The Heater
CAUTION
The installation of electrical appliances
above and in the vicinity of the heater
such as, but not limited to, Plasma
TV, LCD TV, Home Theatre Screens,
Speakers, etc. must comply with their
manufacturers’ instructions.
It is the responsibility of the installer/
end-user to check the installation
instructions of these items and to
ensure the location is suitable.
This caution also extends to, but
is not limited to, ornaments such
as: Paintings, Prints, Photographs,
Tapestries, Mirrors, Stuffed Animals,
etc.
Rinnai does not take any responsibility
for any damage occurring to any items
installed above and in the vicinity of
the heater.
IDEA
Use either a shelf or mantel below the
TV or ornament or alternately you can
construct a recess to mount TV or
ornament on.
Check the manufacturers installation
instructions for these items and ensure
the recess is suitable.
Hearths
Although a solid hearth is not required, if the appliance
is to be installed within 300mm of the oor, it is
recommended that protection is given to any ooring
surface directly in front of the unit as the appliance
produces a large amount of radiant heat and this
might cause damage to ooring and furnishings that
are too close.
300*
X
X
45°
Top Trim
Mantel
Wall
MANTEL MUST NOT EXTEND BEYOND THIS AREA
* NOTE THAT SIDE CLEARANCES CAN BE
REDUCED FROM 300MM TO 50MM
SIDE VIEW
100
45°
FIRE PROOF
BOARD
FIRE PROOF BOARD FOR
MINIMUM HEIGHT OF 300MM
RECESS MUST NOT
EXTEND BEYOND
THIS AREA
When within 300mm of floor
300
300
1000
(Min)
500
(min)
1000
(Recommended
minium height)
1000
(min)
500
(min)