User Guide

RH180 Manual 27
Final Checklist
The water heater is not exposed to corrosive
compounds in the air.
The water heater locaon complies with the
clearances.
The water supply does not contain chemicals or
exceed total hardness that will damage the heat
exchanger.
Ensure the water heater and its water lines are
protected from freezing. Damage due to freezing
is not covered by the warranty.
Conrm that the electricity is supplied from a 120
VAC, 60 Hz power source, is in a properly
grounded circuit, and turned on.
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1.
Verify proper clearances around the vents and air
intakes.
Ensure that the Combuson Air Requirements are
followed that will provide sucient combuson
air for the appliance.
Ensure you have used the correct venng
products for the model installed and that you
have completely followed the venng
manufacturer’s installaon instrucons and these
installaon instrucons.
The water heater must be vented vercally to the
outside of the building or structure.
Purge the water line of all debris. Debris will
damage the water heater. Use a bucket or hose
if necessary.
Ensure the water heater is vented in accordance
with Naonal Fuel Gas Code, ANSI Z223.1/NFPA
54 - latest edion and the requirements of state
or local codes.
Ensure that hot and cold water lines are not
crossed to the unit and are leak free.
Clean the inlet water lter by rst powering OFF
the water heater. Remove the lower enclosure.
Drain and relieve the pressure from the system.
Remove and clean the lter of any debris that
may reduce water ow. Once clean, replace the
lter. Close the drain valve and pressurize the
system. Power the unit back ON and set desired
temperature. For more informaon on cleaning
the lter please reference page 39 secon C.
Ensure that the temperature/pressure relief valve
is installed.
Check for proper water pressure to the water
heater. Minimum water pressure is 20 psi. Rinnai
recommends 30-50 psi for maximum
performance.
A manual gas control valve has been placed in the
gas line to the water heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within
limits.
Conrm that the water heater is rated for the gas
type supplied.
An extension cord or an adapter plug has not
been used with the water heater.
Verify the system is funconing correctly by
connecng your manometer to the gas pressure
test port on the water heater. Operate all gas
appliances in the home or facility at high re. The
inlet gas pressure at the water heater must not
drop below that listed on the rang plate.
Ensure the lower enclosure is installed.
Explain to the customer the importance of not
blocking the vent terminaon or air intake.
Explain to the customer the operaon of the
water heater, safety guidelines, maintenance, and
warranty.
Inform the consumer of the importance of good
water quality and its eects on the warranty.
Leave the enre manual taped to the water
heater, or give the enre manual directly to the
consumer.